Introduction
Emergency shutdown control through the remote emergency power-off (REPO) port.
Standard communication options with a DB-9 serial port, relay output contacts, and programmable signal
inputs.
Optional X-Slot
control.
Advanced power management with the Software Suite CD for graceful shutdowns and power monitoring.
Backed by worldwide agency approvals.
1 1 . . 1 1
O O p p t t i i o o n n s s a a n n d d A A c c c c e e s s s s o o r r i i e e s s
The following options for the Eaton 9155 are available:
1 1 . . 1 1 . . 1 1 P P a a r r a a l l l l e e l l T T i i e e C C a a b b i i n n e e t t
The parallel tie cabinet is used to connect up to three UPSs providing parallel capacity and/or redundant system.
This load sharing system provides more capacity than a single UPS and can provide backup, depending on the
load and configuration. In addition, when one UPS is taken out of service for maintenance or is not operating
properly, a redundant UPS continues to supply uninterrupted power to the critical load. A parallel Powerware
Hot Sync Controller Area Network (CAN) Bridge Card provides connectivity for system metering and
operational mode control. The parallel system consists of two to three UPSs, each with a parallel CAN Bridge
Card, and a parallel tie cabinet.
1 1 . . 1 1 . . 2 2 M M a a i i n n t t e e n n a a n n c c e e B B y y p p a a s s s s M M o o d d u u l l e e ( ( M M B B M M ) )
The optional MBM is installed on the UPS rear panel and is used to bypass the UPS during maintenance or
servicing. The maintenance bypass switch on the MBM provides a Make-Before-Break (MBB) wrap-around
bypass for UPS service without shutting down the load.
1 1 . . 1 1 . . 3 3 P P o o w w e e r r D D i i s s t t r r i i b b u u t t i i o o n n M M o o d d u u l l e e ( ( P P D D M M ) )
The optional PDM provides the same functionality as the MBM and also comes equipped with several different
types of output receptacles.
1 1 . . 1 1 . . 4 4 B B y y p p a a s s s s P P o o w w e e r r M M o o d d u u l l e e
The Eaton Bypass Power Module (BPM) is designed to be a maintenance bypass switch that also contains
flexible output power distribution and mounting options.
The BPM provides added reliability to Eaton uninterruptable power supply (UPS) systems by ensuring
seamless, uninterrupted, no-break transfer as well as a lock-out/tag-out (LOTO) feature to ensure the greatest
safety for UPS technicians and electricians. The BPM also offers output distribution in order to simplify wiring in
a rackmount IT environment, potentially removing the need for a panelboard, breakers, and conduit for
distribution.
1 1 . . 1 1 . . 5 5 I I n n p p u u t t I I s s o o l l a a t t i i o o n n T T r r a a n n s s f f o o r r m m e e r r
The optional input isolation transformer is located at the bottom of a 3-high UPS model. The input isolation
transformer provides a neutral from a 208V or 240V input source with 240V output and can be wired to the UPS
or to an MBM/PDM.
1 1 . . 1 1 . . 6 6 S S e e i i s s m m i i c c K K i i t t
The optional seismic kit secures the UPS and optional EBMs for Zone 4 seismic installations.
2
Eaton 9155 Parallel UPS (8–15 kVA) User's Guide 164201592—Rev E0
®