Download Print this page

CyberData SIP Paging Server Connecting page 4

To a bogen pcm2000 zone paging system
Hide thumbs Also See for SIP Paging Server:

Advertisement

Bogen PCM2000 Zone Paging System with old PCMTIM to SIP Paging Adapter
The IP Endpoint Company
Bogen PCM2000 Application Configuration
PCM
TIM
S1
S2
TEL
S3
INT
S4
SEL
S5
S6
S7
0
1
POWER
TONE
VOLUME
BGM SRC
VOLUME
NIGHT
RING
TEL
LINE
OVER
RIDE
Notes
IN
BGM
This configuration requires PCMTIM, PCMCPU, and PCMZPM modules assembled in this respective 
SRC
RT
order, from left to right. Do not connect the PCMPS2 power supply to the PCMCPU until the 
NC
RLY
module switch settings and wiring connections have been completed.
COM
ONE
NO
NC
When using a Bogen ZPM Module for a single analog Page ALL scenario or  multi‐zone scenario, the 
RLY
COM
CyberData Paging Server must have Bypass DTMF disabled 
TWO
(Web interface>Device tab>Misc Settings).
NO
GND ST
The CyberData Paging Server can pass DTMF tones through the connected terminals however when 
dialing the extension, a menu prompt will be heard for our internal multicast page groups then 
silence. It is required to enter your analog zone number followed by # during this silence. End result 
‐> dial Paging Server, enter 00 during audible menu prompt, a page tone will be heard through the 
handset, and then enter the analog zone number followed by # (e.g. x123, 00, 01#).
S1
S2
Power off PCM system to set dip switches
S3
TEL
INT
1 and 7 to the right and 2 through 6 to the left
S4
SEL
S5
S6
S7
0
1
TEL LINE
6 - Not used
5 - Contact Closure
4 - Dry audio (T)
3 - Dry audio (R)
2 - Contact Closure
1 - Not used
931023B
Connections—VOX Configuration
SIP Paging Server Connections
+ -
s
Page Port Output Connections
Pin Description
1
Fault Sense Input (Common).
2
Fault Sense Input (Sense).
3
Positive 600-Ohm Audio Output
4
Negative 600-Ohm Audio Output
5
Audio Ground Reference.
6
Relay Contact - Common
7
Relay Contact - Normally Open
a.The 600-Ohm audio output of the page port is
also suited for interfaces with lower input
impedances.
b.1 Amp at 30 VDC for continuous loads.
+
-
a
a
b
b

Advertisement

loading
Need help?

Need help?

Do you have a question about the SIP Paging Server and is the answer not in the manual?

Questions and answers