5.6
Measuring points on power module
DANGER - Risk of electric shock from live parts!
¶
Work on electrical systems or equipment must only be performed by qualified electricians or
trained personnel under the guidance and supervision of an electrician.
¶
Observe the electrical engineering safety regulations.
Voltage measurement
Measure mains voltage after power inlet socket connector
Measure mains voltage after device fuse
Measure auxiliary circuit voltage (UZK)
1. Measure primary auxiliary voltage
2. Measure primary auxiliary voltage
Measure auxiliary voltage
Measure controller voltage
Measure reference voltage
Voltage on power module with a 12 V battery
Voltage on power module with a 24 V battery
|
1 689 975 288
2017-06-30
From
To
X4
X2
M1
M2
C58+
C58-
VDD
GND
VDD2
GND
IC 14 Pin 1
GND1 Pin 4
3V3
GND1 Pin 2
3V3ref
GNDA
U
= 12 V
GNDA
actual
U
= 24 V
GNDA
actual
Value, approx.
230 V
230 V
360 V
13 V
12 V
12 V
3.3 V
3.3 V
0.85 V
1.7 V
Robert Bosch GmbH