Replacing The Fan; Replacing The Battery Connection - Bosch BAT 690 Repair Instructions

Charger for 12 volt and 24 volt batteries
Hide thumbs Also See for BAT 690:
Table of Contents

Advertisement

Available languages

Available languages

en
26 | BAT 690 | Assembly / disassembly
4.5

Replacing the fan

1. BAT 690 to be disconnected from the mains voltage
system.
2. Remove the power supply cable from BAT 690.
3. Remove housing caps (see sec. 4.1).
4. Remove top part of housing (see sec. 4.2.1).
5. Remove power module with defective fan.
6. Remove connecting cable for fan from power
module (see sec. 6).
7. Remove Torx screws (fig. 15, item 1) from the fan.
8. Replace the fan (fig. 15, item 1).
2
1
Fig. 15:
Replacing the fan
1 Torx screws
2 Fan
9. Fasten new fan with Torx screws.
10. Attach connecting cable for fan to power module
(see sec. 6).
11. Secure power module to lower part of housing.
12. Secure battery connecting cables to power module
(see sec. 6).
13. Attach the connecting cables for the power
connector to the power module (see sec. 6).
14. Secure top part of housing (see sec. 4.2.4).
15. Switch on the BAT 690.
16. Perform a self test.
|
1 689 975 288
2017-06-30
4.6

Replacing the battery connection

1. BAT 690 to be disconnected from the mains voltage
system.
2. Remove the power supply cable from BAT 690.
3. Remove housing caps (see sec. 4.1).
4. Remove top part of housing (see sec. 4.2.1).
5. Remove connecting cables of port for battery
charging cable from power module 1 and power
module 2 (see sec. 6).
6. Remove connection for battery charging cable.
1
2
4
Fig. 16:
Remove battery connection
1 Remove connecting cables of port for battery charging cable for
power module 1
2 Remove connecting cables of port for battery charging cable for
power module 2
3 Connection for battery charging cable
4 Power module 1
5 Power module 2
7. Fit new connection for battery charging cable with
connecting cables to power module 1 and power
module 2.
8. Secure connecting cables of port for battery
charging cable on power module 1 and power
module 2 (see sec. 6).
9. Secure top part of housing (see sec. 4.2.4).
5
3
Robert Bosch GmbH

Advertisement

Chapters

Table of Contents
loading