Measuring Points On The Power Module - Bosch BAT 645 Repair Instructions

Charger for 12 volt and 24 volt batteries
Table of Contents

Advertisement

Available languages

Available languages

en
26 | BAT 645 | Faults & Troubleshooting
5.6

Measuring points on the power module

DANGER - Risk of electric shock from live parts!
Work on electrical systems or equipment must only be performed by qualified electricians or
trained personnel under the guidance and supervision of an electrician.
Observe the electrical engineering safety regulations.
Voltage measurement
Measure the voltage after the power inlet socket connector
Measure the voltage after the device fuse
Measure the link voltage (UZK)
Measure the 1st primary auxiliary voltage
Measure the 2nd primary auxiliary voltage
Measure the auxiliary voltage
Measure the controller voltage
Measure the reference voltage
Voltage on the power module with a 12-V battery
Voltage on the power module with a 24-V battery
|
1 689 975 285
2017-06-30
From
To
X4
X2
M1
M2
C58+
C58-
VDD
GND
VDD2
GND
IC 14 Pin 1
GND1 Pin 4
3V3
GND1 Pin 2
3V3ref
GNDA
U
= 12 V
GNDA
ist
U
= 24 V
GNDA
ist
Value, approx.
230 V
230 V
360 V
13 V
12 V
12 V
3.3 V
3.3 V
0.85 V
1.7 V
Robert Bosch GmbH