Setting Transmitter Operating Frequency
The Operating Frequency of the SMB Series
transmitter is displayed either in MHz or as a
two-digit hexadecimal number. Pressing the FREQ
button toggles between the two display modes.
The frequency can be set with the unit in Standby
Mode or while powered up for normal operation.
Note: You must first find a clear frequency
with the receiver, then set the transmitter to
match.
To change the Operating Frequency of the SMB
Series transmitter:
1)
Press the FREQ button to enter this screen.
Note: The default display is in MHz. Pressing the FREQ button again
displays the operating frequency as a two-digit hexadecimal number.
2)
While holding the FREQ button, use the Up or Down arrow buttons to
move the operating frequency up or down in 100 kHz increments from
the current setting. Holding the Up or Down arrows will cause rapid scroll-
ing through the frequencies.
Note: The operating frequency displayed on the LCD wraps as it
reaches the upper or lower end of its range. Thus, if you intend to
move the operating frequency from the lower end of the range to the
upper end, it may be faster to do this by using the Down arrow until the
frequency wraps to the upper end
www.lectrosonics.com
Frequency displayed
in MHz
Frequency displayed as
two-digit hexadecimal
number
5