P4
FL
P3
EN
PRESTIGE SOLO (2 PUMPS)
7
PRESET CONFIGURATION 12
X100
Y/Gr
Y/Gr
FR
Y/Gr
Y/Gr
Flex 4
Flex 6
Y/Gr
Y/Gr
ERR
P4
10 11 12 13 14 15 16
Y/Gr
Mix open
CH1/CH2/
NL
DHW
B
X10
W
High and Low temperature heating circuit, possibly with optional outdoor
B
V
temperature sensor and room thermostat, and with DHW circuit.
X12
B
W
ES
Br
B
Br
LOW T° SCHEMA : 4a
X9
B
Y/Gr
Y/Gr
CH2
CH1
Y/Gr
IT
Y/Gr
W
Y/Gr
B
Y/Gr
V
Y/Gr
P14
B
Or
B
DE
Bk
B
P13
Y/Gr
F00
PL
W
2
P3
W
W
1
RU
B
Y/Gr
Br
2
en
2-28
Br
Bk
NTC 5
NTC 2
NTC 1
8
B
9
10
11
B
12
1
2
3
4
5
1
1
1
1 2 3 4 5
2 1
2 1
2 1
2 1
Pump Configuration 12
Flex 3
Flex 2
Flex 1
P3
DHW
CH
CH2
DHW
CH1 low
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1
2
3
4
5
6
1
2
3
4
5
X1
X3
7
8
9
10 11
12
6
7
8
9
10
Br
Bk
B
B
ACV Max
5AT Fuse
DHW
Low
5AT Fuse
27
CH
DHW
5AT Fuse
5AT Fuse
X101
B
N
N
N
230 V ~ 50Hz
Y/Gr
1
L
L
Br
L
15
13
14
16
3
2
1
1
2
3
4
5
X20
4
6
1
2
3
6
7
8
9
10
Bk
1
2
3
4
3 2 1
1 2 3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
Flex 5
FL
Mix close
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
1
2
3
4
5
6
7
1
2
3
4
5
1
2
3
X2
X11
8
9
10 11 12
13
14
6
7
8
9
10
4
5
6
3
2
1
X18
5AT Fuse
* The room thermostat 1 always controls the low temperature system.
Prestige
P4
Main
Screen
5AT Fuse
W
Warm water
Cold water
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 2 • B
B
B
V
Br
Electrical board terminals
Terminal name --> Connected to
Y/Gr
Y/Gr
............. P4
Br
V
B
B
Br
W
............. Flame
B
B
Y/Gr
Y/Gr
Br
............. P3
W
B
B
Or
............. ERR
B
Y/Gr
Y/Gr
B
B
............. DHW
W
Br
X16
Y/Gr
Y/Gr
X15
17
B
B
............. CH
V
Br
Bus A
18
X7
Bus - Ground
Bus B
26
............. DHW sensor (NTC3)
Y/Gr
Y/Gr
X4
19
NTC 3
R
Br
V
W
B
B
............. Optional outdoor temp. sensor (NTC4)
Br
20
W
NTC 4
V
B
B
Bk
Bk
X6
Y/Gr
Y/Gr
R
............. Optional room thermostat 1*
21
Br
W
1
B
B
0-10 Volt - Input
22
W
0-10 Volt - Ground
V
Cascade sensor - Input
23
X5
Bk
Cascade sensor - Ground
Bk
BK
Y
Y
Y
24
R
2
W
R
BK
R
Y
ACVMax interface settings using the Installer menu
R
W
W
(Installer code needed, see
W
Bk
V
Sub-
item
Sub-item
V
Y
screen
R
W
Model
V
Bk
Bk
Bk
Bk
25
Bk
Bk
16
Or
R
Pump Settings
Preset Pump Config
R
R
Bk
Heating Operation
W
W
W
V
Bk
Y
Y
Demand
Bk
BK
Y
Y
Y
Y
Y
Y
Y
R
Y
Y
W
Y
Y
CH2 Circuit
Y
Y
R
BK
Y
Y
R
Y
DHW Operation
Y
Y
R
Y
Y
Y
W
Y
W
Demand
W
W
W
Bk
V
W
W
W
V
W
Y
W
W
W
W
W
W
Bk
Bk
Bk
Bk
Or
R
-->P4 pump
-->Motorized 3-way valve CLOSE
-->P3 pump (CH2 circuit)
-->Motorized 3-way valve OPEN
-->DHW pump
-->CH pump (low temp circuit)
):
"Installer Code"
Required selection
Prestige Solo (Pre-Set)
Config 12
Enabled (
)
Thermostat and Outd.
curve
Enabled
Enabled (
)
Sensor

Hide quick links:

Advertisement

Table of Contents
loading