PRESTIGE SOLO (2 PUMPS)
7
X100
PRESET CONFIGURATION 7
Y/Gr
Y/Gr
Y/Gr
10 11 12 13 14 15 16
Y/Gr
Flex 4
Flex 6
Y/Gr
ERR
P4
Y/Gr
Y/Gr
B
Error
CH1/CH2
X10
W
B
V
X12
B
W
Br
High and Low temperature heating circuits, with room control on Heating Circuit
B
Br
1 (CH1) and possible second room control, possibly with optional outdoor
X9
B
temperature sensor and room thermostat.
LOW T° SCHEMA : 1
Y/Gr
Warm water
W
Y/Gr
Cold water
B
Y/Gr
V
P14
Y/Gr
B
Y/Gr
Or
B
Y/Gr
Y/Gr
Bk
B
P13
Y/Gr
F00
W
B
N
Y/Gr
Br
L
2
Essential recommendations for the correct operation of the system
•
Low temperature sensor is not shown here, but make sure to install one to control the
circuit (using the additional wiring made available in the optional wiring kit).
•
Low temperature cut-out thermostat is not shown here, but make sure to install one to
protect the low temperature circuit (to be connected to X20 terminal, ref. 13 on Prestige
42-50-75-100-120 Solo wiring diagrams ).
NTC 5
NTC 2
NTC 1
8
9
10
11
12
1
2
3
4
5
Br
Bk
B
1
1
B
1
1 2 3 4 5
2 1
2 1
2 1
2 1
Pump Configuration 7
Flex 3
Flex 2
Flex 1
P3
DHW
CH
1 2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Mix open
DHW
CH1 low
1
2
3
4
5
6
1
2
3
4
5
X1
X3
7
8
9
10 11
12
6
7
8
9
10
Br
Bk
B
B
ACV Max
5AT Fuse
5AT Fuse
5AT Fuse
27
Prestige
CH
Low
W
2
W
X101
1
B
N
5AT Fuse
N
230 V ~ 50Hz
Y/Gr
5AT Fuse
1
L
Br
L
5AT Fuse
Y/Gr
15
13
14
16
1
2
3
4
5
X20
4
6
1
2
3
6
7
8
9
10
Bk
1
2
3
3
2
1
4
3 2 1
1 2 3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
Electrical board terminals
Y/Gr
Flex 5
Y/Gr
FL
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
Mix close
1
2
3
4
5
6
7
1
2
3
4
5
1
2
3
X2
X11
Y/Gr
8
9
10 11 12
13
14
6
7
8
9
10
4
5
6
Y/Gr
3
2
1
X18
Y/Gr
Bk
Y/Gr
R
W
* The room thermostat 1 always controls the low temperature system.
V
BK
Y
R
W
BK
Y
R
W
Main
Bk
Screen
V
Bk
W
Bk
Bk
R
Or
P4
R
W
W
V
Y
BK
Y
Y
Y
R
Y
W
Y
Y
BK
Y
Y
Y
R
Y
W
Y
W
Bk
W
V
W
W
W
W
Bk
Bk
Or
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 2 • B
Y/Gr
B
B
V
Br
Terminal name --> Connected to
Y/Gr
............. P4
Br
V
B
B
W
Br
............. FL
B
B
Y/Gr
............. P3
Br
W
B
B
Or
X16
............. ERR
B
X15
17
Y/Gr
B
B
............. DHW
W
Br
Y/Gr
B
B
............. CH
V
Br
Bus A
18
X7
Bus - Ground
Bus B
26
19
X4
NTC 3
20
............. Optional outdoor temp. sensor (NTC4)
NTC 4
Y/Gr
X6
R
Br
V
21
............. Optional room thermostat 1 *
B
1
B
W
Br
W
V
B
B
0-10 Volt - Input
Bk
22
Y/Gr
0-10 Volt - Ground
Br
W
Cascade sensor - Input
X5
23
B
B
Cascade sensor - Ground
24
2
Bk
Bk
Y
Y
ACVMax interface settings using the Installer menu
R
R
(Installer code needed, see
W
W
Sub-
item
Sub-item
V
screen
Y
16
25
R
Model
W
V
Bk
Bk
Pump Settings
Preset Pump Config
Bk
Heating Operation
R
Bk
W
Bk
Demand
Bk
Y
Y
Y
Y
Y
Y
CH2 Circuit
Y
R
Y
R
Y
DHW Operation
Y
Y
W
Y
Demand
W
W
V
W
Y
W
W
W
W
Bk
Bk
-->P4 pump
-->Motorized 3-way valve CLOSE
-->Motorized 3-way valve OPEN
-->Error (Alarm)
-->None
-->CH pump (low temp circuit)
):
"Installer Code"
Required selection
Prestige Solo (Pre-Set)
Config 7
Enabled (
)
Thermostat and Outd.
curve
Enabled
Enabled (
)
Sensor
en
2-25
EN
FR
NL
ES
IT
DE
PL
RU