Manual Operation ( ) - ACV Prestige 24 Solo Installer's Handbook

Heating systems controlled with acvmax
Table of Contents

Advertisement

EN
ACVMAX DESCRIPTION AND OPERATION
Manual Operation (
)
FR
"Installer Code"
Manual Operation
NL
ES
General remark
IT
To ensure the operation of
the heating system, make
sure to switch on one of the
pumps.
DE
PL
RU
en
1-22
FAN - Press the OK button while the FAN icon is highlighted to manually fire the burner and power the CH (1) circulator.
Manual Operation
Press the LEFT and RIGHT buttons to adjust the firing rate from 0% (Low Fire) to 100% (High Fire).
Released
FAN
O
Hold down the LEFT or RIGHT buttons to rapidly increase or decrease the firing rate.
CH1
O
Press the OK button again while the FAN icon is highlighted to shutdown the burner when finished.
DHW
O
CH2
CH1 - Press the OK button while the CH1 icon is highlighted to manually power the CH 1 circulator(s) as in CH demand.
Manual Operation
Released
Press the OK button again while the CH1 icon is highlighted to shutdown the CH 1 circulator(s).
FAN
O
CH1
The auxiliary Appliance circulator is also powered when the CH 1 circulator is manually enabled.
O
DHW
O
CH2
DHW - Press the OK button while the DHW icon is highlighted to manually power the DHW circulator(s) as in DHW demand.
Manual Operation
Released
Press the OK button again while the DHW icon is highlighted to shutdown the DHW circulator(s).
FAN
O
CH1
The auxiliary Appliance circulator is also powered when the DHW circulator is manually enabled.
O
DHW
O
CH2
CH2 - Press the OK button while the CH2 icon is highlighted to manually power the CH2 circulator(s) as in CH demand.
Manual Operation
Press the OK button again while the CH2 icon is highlighted to shutdown the CH2 circulator(s).
Released
FAN
O
CH1
O
DHW
O
CH2
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 1 • B