ACV Prestige 24 Solo Installer's Handbook page 21

Heating systems controlled with acvmax
Table of Contents

Advertisement

ACVMAX DESCRIPTION AND OPERATION
Boiler Settings
Boiler Settings
Model
Solo (2 pumps)
Current Pump Con g
Lockout Temp.
221°F [105°C]
Preset Pump Con g
Modbus Address
1
Flexible Pump Con g
Pump settings
Ignition Level
3100rpm
Mix zone high limit
45°C
Current Pump Con g
Preset Pump Con g
Flexible Pump Con g
Current Pump Con g
Preset Pump Con g
Flexible Pump Con g
The Pump Settings menu allows to choose the right pump configuration to the chosen hydraulic configuration.
Pump Settings
The Current Pump Config indicates which configuration is currently selected for the appliance.
Con g 16
Two appliance configuration modes are available : a preset configuration mode and a flexible configuration mode.
Press the UP or DOWN buttons to scroll through the options, then on OK to validate your selection.
Pump Settings
Preset Pump Con g
Con g 1
Con g 16
Con g 2
Con g 3
Con g 4
Con g 5
Con g 6
Pump Settings
Flexible Pump Con g
Modi ed
Flex. Relay 1 (CH)
Flex. Relay 2 (DHW)
Flex. Relay 3 (P3)
Flex. Relay 4 (ERR)
Flex. Relay 5 (Flame)
Flex. Relay 6 (P4)
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 1 • B
In the Preset Pump Config. (preferred selection) you can choose from a number of preset pump configurations.
Only the configurations usable with a certain model/type of appliance will appear in the list. The configurations
"User's
Guide". Each configuration is detailed through one or several hydraulic dia-
are detailed in Volume 2,
grams, a table indicating the electrical connections and a list of the parameters to be defined in ACVMax.
Press the UP or DOWN buttons to scroll through the settings, then on OK to validate your selection.
The Flexible Pump Config. menu allows to customize the pump configuration to the chosen hydraulic configu-
ration. Only select this option when the preset configurations do not offer you a solution. In this menu you have to
choose per relay for which heat demand / function it will be activated. The relays are allocated as follows by default
(see picture below for physical location on the optional
terminal blocks) :
Flex. Relay 1 .................. CH
Flex. Relay 2 .................. DHW
Flex. Relay 3 .................. P3
Flex. Relay 4 .................. ERR
Flex. Relay 5 .................. FL
Flex. Relay 6 .................. P4
Press the UP or DOWN buttons to scroll through the
settings, then on OK to validate your selection.
The use of the Flexible Pump Config.
menu is not possible for the Solo/
Excellence (3 way valve).
Prestige Solo
P4
FL
P3
X100
X100
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16
B
W
B
V
B
W
W
B
V
B
Or
B
EN
FR
NL
ES
IT
DE
PL
RU
X10
Flame
CH
X12
DHW
P3
P14
P4
Error
en
1-17