PUMP PWM
M
C
PRESTIGE SOLO/EXCEL (3-WAY VALVE)
9
10
3 2 1
3 2 1
STEPPER
1
2
3
4
5
M
PRESET CONFIGURATION 3
A B C D
1 2 3 4 5
Y/Gr
Y/Gr
Y/Gr
Pump Configuration 3
Y/Gr
Flex 4
Flex 6
Y/Gr
Y/Gr
ERR
P4
Y/Gr
Error
CH2
1 2 3 4 5 6 7 8 9 10 11 12
B
X10
W
1
2
3
4
B
7
8
9
10 11
V
X12
B
W
Br
High and Low temperature heating circuits, with optional outdoor temperature
B
X9
sensor and room thermostats, and with DHW circuit.
Br
B
Y/Gr
Y/Gr
Y/Gr
W
CH2
CH1
Low
B
Y/Gr
V
Y/Gr
P14
B
Y/Gr
Or
Y/Gr
B
Bk
B
P13
Y/Gr
F00
27
W
P3
W
2
P4
W
1
B
Y/Gr
Br
2
Essential recommendations for the correct operation of the system
•
Low temperature sensor is not shown here, but make sure to install one to control the
circuit (using the additional wiring made available in the optional wiring kit).
•
Low temperature cut-out thermostat is not shown here, but make sure to install one to
protect the low temperature circuit (to be connected to X20 terminal, ref. 14 on Prestige
24-32 Solo/Excellence wiring diagram).
NTC 5
NTC 2
NTC 1
14
Br
Bk
11
12
13
15
X20
B
B
Bk
1
1
1
2 1
2 1
2 1
4 3 2 1
Flex 3
Flex 2
Flex 1
P3
DHW
CH
CH1/CH2/
CH1
Mix open
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
DHW
5
6
1
2
3
4
5
1
2
3
4
5
6
7
X1
X3
12
6
7
8
9
10
8
9
10 11 12
13
14
Br
Bk
B
B
ACV Max
5AT Fuse
5AT Fuse
5AT Fuse
Prestige
5AT Fuse
230 V ~ 50Hz
5AT Fuse
1
5AT Fuse
Warm water
Cold water
B
V
17
16
18
1
2
3
4
5
3
2
1
4
6
1
2
3
6
7
8
9
10
Electrical board terminals
1
2
3
1 2 3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
Y/Gr
V
B
W
B
Flex 5
Y/Gr
W
FL
B
Or
Mix close
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
B
Y/Gr
X16
1
2
3
4
5
1
2
3
B
X2
X11
X15
W
Y/Gr
6
7
8
9
10
4
5
6
B
V
X7
3
2
1
25
X4
X18
Y/Gr
V
B
X6
DHW
W
B
Bk
Y/Gr
R
W
B
X5
W
V
BK
Y
R
W
*The room thermostat 1 always controls the low temperature system.
BK
Y
R
W
Bk
V
Main
Sub-
26
Screen
screen
Bk
Bk
Bk
R
W
Or
R
W
W
V
Y
BK
Y
Y
Y
R
Y
W
Y
Y
BK
Y
Y
Y
R
Y
W
Y
W
Bk
W
V
W
W
W
W
Bk
Bk
Or
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 2 • B
B
Br
Terminal name --> Connected to
Y/Gr
............. P4
Br
B
Br
............. FL
B
Y/Gr
............. P3
Br
B
............. ERR
Y/Gr
B
............. DHW
Br
Y/Gr
B
............. CH
Br
Bus A
19
Bus - Ground
Bus B
............. DHW sensor (NTC3)
20
NTC 3
Y/Gr
............. Optional outdoor temp. sensor (NTC4)
21
Br
R
NTC 4
W
B
Br
............. Optional room thermostat 1*
22
V
B
1
Bk
Y/Gr
Br
0-10 Volt - Input
23
B
0-10 Volt - Ground
Bk
............. Optional room thermostat 2
24
Bk
2
Y
Y
R
R
W
ACVMax interface settings using the Installer menu
W
(Installer code needed, see
"Installer Code"
V
Y
item
Sub-item
R
W
V
Bk
Bk
Bk
Model
R
Pump Settings
Preset Pump Config
Bk
W
Heating Operation
Bk
Bk
Y
Y
Y
Y
Y
Y
CH2 Circuit
Y
R
Y
R
Y
Demand
Y
Y
W
Y
W
DHW Operation
W
V
W
Demand
Y
W
W
W
W
Bk
Bk
R
EN
--> P4 pump (CH2 circuit)
FR
--> Motorized 3-way valve CLOSE
--> P3 pump (CH1
circuit)
Low
--> Error (Alarm)
NL
--> Motorized 3-way valve OPEN
--> Built-in circulator pump
ES
IT
DE
PL
):
Required selection
RU
Prestige 3WV (Pre-set)
Solo/Excellence 3
Enabled (
)
Enabled
Thermostat and Outd.
curve
Enabled (
)
Sensor
en
2-9