ACV Prestige 24 Solo Installer's Handbook page 56

Heating systems controlled with acvmax
Table of Contents

Advertisement

FL
P3
EN
PRESTIGE SOLO (2 PUMPS)
7
High and Low temperature heating circuits, with room control on Heating Circuit
1
2
X100
1 (CH1) and possible second room control, possibly with optional outdoor
Y/Gr
1 2 3 4 5
temperature sensor and room thermostat, and with DHW circuit.
Y/Gr
FR
Y/Gr
Y/Gr
Y/Gr
Y/Gr
11 12 13 14 15 16
Y/Gr
Warm water
NL
LOW T° SCHEMA : 2
Cold water
1 2 3 4 5 6 7 8 9 10 11 12
B
X10
W
B
V
X12
B
W
ES
Br
B
Br
X9
B
Y/Gr
Y/Gr
Y/Gr
IT
Y/Gr
W
Y/Gr
B
Y/Gr
V
W
Y/Gr
P14
B
2
Or
W
1
B
DE
Bk
B
P13
Y/Gr
F00
PL
W
RU
B
N
Y/Gr
Br
L
Flex 4
Flex 6
2
ERR
P4
Error
CH1/CH2
en
2-26
Br
Bk
NTC 5
NTC 2
NTC 1
8
9
10
11
12
B
B
X20
3
4
5
1
1
1
2 1
2 1
2 1
2 1
4
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6 7 8 9 10 11 12 13 14
1
2
3
4
5
6
1
2
3
4
5
1
2
X1
X3
7
8
9
10 11
12
6
7
8
9
10
8
9
Br
Bk
B
B
ACV Max
5AT Fuse
Prestige
5AT Fuse
CH
5AT Fuse
Low
DHW
27
P4
5AT Fuse
5AT Fuse
X101
B
5AT Fuse
N
N
230 V ~ 50Hz
Y/Gr
1
L
Br
L
Pump Configuration 7
Flex 3
Flex 2
Flex 1
P3
DHW
CH
Mix open
DHW
CH1 low
15
13
14
16
3
2
1
1
2
3
4
5
4
6
Electrical board terminals
1
2
3
6
7
8
9
10
Bk
1
2
3
3 2 1
1 2 3
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
1 2 3 4 5 6 7 8 9 10
1 2 3 4 5 6
3
4
5
6
7
1
2
3
4
5
1
2
3
X2
X11
X15
10 11 12
13
14
6
7
8
9
10
4
5
6
3
2
1
26
X18
* The room thermostat 1 always controls the low temperature system.
Main
Screen
W
Flex 5
FL
Mix close
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 2 • B
B
B
Br
V
Terminal name --> Connected to
Y/Gr
Y/Gr
............. P4
Br
V
B
B
Br
W
............. FL
B
B
Y/Gr
Y/Gr
............. P3
Br
W
B
B
Or
............. ERR
B
Y/Gr
Y/Gr
B
B
............. DHW
W
Br
X16
Y/Gr
Y/Gr
17
B
B
............. CH
V
Br
Bus A
18
X7
Bus - Ground
Bus B
............. DHW sensor (NTC3)
Y/Gr
Y/Gr
X4
19
NTC 3
Br
V
R
W
B
B
............. Optional outdoor temp. sensor (NTC4)
Br
20
W
NTC 4
V
B
B
Bk
Bk
X6
Y/Gr
Y/Gr
............. Optional room thermostat 1*
R
21
Br
W
1
B
B
0-10 Volt - Input
22
0-10 Volt - Ground
W
Cascade sensor - Input
V
23
X5
Cascade sensor - Ground
Bk
Bk
BK
Y
............. Optional room thermostat 2
Y
Y
24
R
2
W
R
BK
R
Y
R
W
W
W
ACVMax interface settings using the Installer menu
(Installer code needed, see
Bk
V
V
Y
R
Sub-
item
Sub-item
W
screen
V
Bk
Bk
Bk
25
Bk
Bk
16
Bk
R
Or
Model
R
R
Bk
Pump Settings
Preset Pump Config
W
W
W
V
Bk
Heating Operation
Bk
Y
Y
BK
Y
Y
Y
Y
Y
Y
Y
R
Y
Y
Demand
W
Y
Y
R
Y
Y
BK
R
Y
Y
Y
Y
Y
CH2 Circuit
R
Y
Y
W
W
Y
Y
W
DHW Operation
W
W
Bk
V
Demand
W
W
V
Y
W
W
W
W
W
W
W
W
Bk
Bk
Bk
Bk
Or
R
--> P4 pump
--> Motorized 3-way valve CLOSE
--> Motorized 3-way valve OPEN
--> Error (Alarm)
--> DHW pump
--> CH pump (low temp circuit)
):
"Installer Code"
Required selection
Prestige Solo (Pre-Set)
Config 7
Enabled (
)
Thermostat and Outd.
curve
Enabled
Enabled (
)
Sensor