ACV Prestige 24 Solo Installer's Handbook page 22

Heating systems controlled with acvmax
Table of Contents

Advertisement

EN
ACVMAX DESCRIPTION AND OPERATION
Boiler Settings
FR
Boiler Settings
Model
Solo (2 pumps)
Lockout Temp.
221°F [105°C]
Modbus Address
1
Pump Settings
Pump settings
NL
Ignition Level
3100rpm
Current Pump Con g
Mix zone high limit
45°C
Preset Pump Con g
Flexible Pump Con g
Flexible Pump Con g
Flex. Relay 1 (CH)
ES
Flex. Relay 2 (DHW)
Flex. Relay 3 (P3)
Flex. Relay 4 (ERR)
Flex. Relay 5 (Flame)
Flex. Relay 6 (P4)
IT
DE
PL
RU
en
1-18
Modi ed
Flex. Relay 1 (CH)
CH1
On
CH2
O
DHW
O
MIX OPEN
O
MIX CLOSE
O
ERROR
O
FLAME
O
Flex. Relay 1 (CH)
CH2
O
DHW
O
MIX OPEN
O
MIX CLOSE
O
ERROR
O
FLAME
O
Save & Exit
Each relay function has several options. Activation will happen when one of the following options has been chosen: CH1,
CH2, DHW, MIX OPEN, MIX CLOSE, ERROR, FLAME.
More than one action can be chosen for one relay (one relay can become active for CH1 , CH2 and DHW demand when needed.)
Press the UP or DOWN buttons to scroll through the settings, then on OK to toggle between the On/Off status of each
relay. Then go to the next line, until you reach the last line.
When selecting CH 1, the relay is activated at CH 1 demand.
When selecting CH 2, the relay is activated at CH 2 demand.
When selecting DHW, the relay is activated at DHW demand.
When selecting Mix Open, the Mixing valve open input is activated. Provided there is a mixing valve in the hydraulic
circuit, runtime is assumed to be 120 sec.
When selecting Mix Close, the Mixing valve close input is activated. Provided there is a mixing valve in the hydraulic
circuit, runtime is assumed to be 120 sec.
When selecting ERROR, the relay is activated on error.
When selecting FLAME, the relay is activated when appliance is running and a flame signal has been detected.
By pushing the RIGHT button then OK, you go back to the previous screen, but THE CHANGED VALUES ARE
NOT STORED in the memory (Quick escape route).
To save your changes, make sure to scroll down to the last line of the screen and to select Save & Exit. Then
press on OK to activate the function.
Press on OK to activate Save & Exit. This will ensure that the changed data are stored in the appliance.
The Installer's Handbook - ACVMax: A1004308 - 660Y2900 - Volume 1 • B