Soft-Switch 26: Miscellaneous; Soft-Switch 27: Miscellaneous - Xerox MF Series Technical Document

Table of Contents

Advertisement

Bit
Value
6
0
7
0
8
0
7.3.26 S
-
OFT
SWITCH
Bit
Value
1
0
2
0
3
0
4
0
5
0
6
0
7
1
8
0
7.3.27 S
-
OFT
SWITCH
Bit
Value
1
0
2
0
3
0
4
1
5
0
6
0
7
0
8
0
- 17 -
SOS-TXADTERMINAL: Transmit the terminal address in the server number
# 0: No
1: Yes
SOS-RXADTERMINAL: Receive the terminal address in the server number
# 0: No
1: Yes
SOS-EXPBITPDF: Export the attached file format field (Image/PDF) when exporting the
directory via e-mail.
# 0: No
1: Yes
ATTENTION: If the directory is exported to a machine which does not support this format,
the machine (receiver) will loose its current directory, and won't be able to restore the new
one.
26: M
ISCELLANEOUS
Display the SMS type
#0: No default SMS type menu
1: With SMS type menu
LOGIN authentification activation
#0: LOGIN authentification enabled
1: LOGIN authentification disabled
With or without dual chip consumable card
#0: With dual chip card->display PUT IN OTHER WAY sync chip detected
1: No dual chip card management-> display WRONG CARD if sync chip detected
Restriction on USB function
#0: No
1: Yes
With or without duplication of on page passage threshold
#0: No duplication: NBI_SUP_B (1cm)
1: Duplication: NBI_SUP_B * 2 (2 cm)
RR/RNR regulation limitation to 4 in T30
#0: No limitation
1: With limitation
Double alternation optocoupler use
#0: Optocoupleur mono alternation
1: Optocoupleur double alternation
Restriction of CCD lamp extinction
#0: With extinction
1: No extinction
27: M
ISCELLANEOUS
Size of remote readout serial number
#1000: 8 digits remote readout serial number
1111: 15 digits remote readout serial number (only for EGT for now)
Waiting time before validation of unexpected modulation in comparison with expected
modulation. (~/driver/m_lucent/sms_m_dp2v/src/dpmain.c)
# 00 = 60 + 0*30 ms= 60 ms
01 = 60 + 1*30 ms = 90 ms
02 = 60 + 2*30 ms = 120 ms
03 = 60 + 3*30 ms = 150 ms
04 = 60 + 4*30 ms = 180 ms
05 = 60 + 5*30 ms = 210 ms
06 = 60 + 6*30 ms = 240 ms
......
0F = 60 + 15*30 ms = 510 ms