2. Remove two screws and disconnect the Fusing
Unit.
4136D021AA
3. Remove two bushings and the Pressure Roller.
4136D022AA
Precautions for Installation of Bushings
• Make sure that the slits in the bushing are properly
aligned with the rib of the Fusing Unit.
4136D040AA
4. Remove one screw and the terminal block.
5. Pull out the Fusing Roller Heater Lamp.
NOTES
• Do not touch the surface of the glass of the Fusing
Roller Heater Lamp with bare hands.
• When reinstalling the Fusing Roller Heater Lamp,
make sure that the side of the lamp having a volt-
4136D023AB
age marking faces the gear side.
6. Pull out the drive gear from the Fusing Roller.
7. Pull out the Fusing Roller.
NOTE
• When removing and reinstalling the Fusing Roller,
keep the Fusing Roller Paper Separator Fingers in
their raised position. Use care not to damage the
surface of the Fusing Roller.
4136D024AB