D6
SUBJECT: CIS
Tools
• Phillips screwdriver.
Preliminary steps
Attention - The active surface of the CIS is fragile and light-sensitive. Take care to protect it and to
expose it to light as little as possible during the operation.
• Remove the control panel / scanner chassis - printer (worksheet D5).
Disassembly
• Free the control panel flat cable from the cable guide.
• Remove the four mounting screws. Remove the CIS support while releasing the control panel
flat cable.
• Disconnect the CIS flat cable and its connector. Remove the CIS flat cable.
Assembly
• Unpack and visually check the new parts.
• Equip the CIS support with its flat cable. Pass the control panel flat cable into the correspond-
ing passage (see figure).
• Put the CIS support in place, screw in and tighten the four mounting screws.
• Pass the control panel flat cable into its cable guide. Pass the control panel and CIS flat cables
under the control panel unlocking shaft.
- 15 -
SUPPORT
Mounting screws
- CIS
FLAT CABLE
Passage for the
control panel flat cable
MG 252 787 467 - A