Assa Abloy Yale Secure Connect MZ-1 Manual

Smart home

Advertisement

Quick Links

Yale Smart Home
Alarm Manual
MZ-1 . MZ-8
Device Images may differ per region.
The smarter way to secure your home
.
1

Advertisement

Table of Contents
loading

Summary of Contents for Assa Abloy Yale Secure Connect MZ-1

  • Page 1 Yale Smart Home Alarm Manual MZ-1 . MZ-8 Device Images may differ per region. The smarter way to secure your home...
  • Page 2 A smart home starts with a smart door lock. You can upgrade your system with a stand alone smart door lock or as connected with the Yale Smart Living Home App.
  • Page 3: Table Of Contents

    (02) Introduction (02) Contents Contents Thank you for choosing the Ya (02) Thank you for choosi 1. Location planning been designed with the user i Location planning been designed with All the components are self 2. Un-pack & power devices units.
  • Page 4: Location Planning

    Yale® is a registered Take care that the correct tools are used. Wear goggles or trademark. © 2019 ASSA ABLOY. All rights reserved. trademark. © 2018 ASSA ABLOY. All rights reserved. ift carpets or run cables.
  • Page 5 (GB) Step by step index - (03) Accessories vary depending on kit E) Installation - Smoke Detector External Siren L e a te ry B at ff > < O P o w m has L A N L e a t e r y Mount on a ceiling in main B a t...
  • Page 6 (03) Unpacking the devices Unpacking the devices • L e a e ry B a tt > Accessories vary depending on kit < O P o w Smart Hub L A N 1. Plug in the power adaptor and connect the Smart Hub to your internet router using the cable provided. Router NOT INCLUDED (03)
  • Page 7 (GB) Installation - (IT) Installazione - (DE) Installation - (NO) Installasjon - (SE (DK) Installation. Key Pad Remove battery strips Panic button A Panic button B Learn button= Press 8 and 9 together Away T) Installazione - (DE) Installation - (NO) Installasjon - (SE) Insta Disarm Part Arm HomeArm...
  • Page 8 Unpacking the devices Unpacking the devices (11) • stallation - (21) External Siren (GB) Installation - (IT) Installazione - (DE) Installation - (NO) Installasjon - (SE) Installation - (DK) Installation. WARNING The Siren is very loud! Take care not to activate the Siren tamper switch unnecessarily.
  • Page 9 Key Fob (11) SR-KF SR-KF Smoke Detector SR-KF SR-SD SR-SD Note: The Yale smoke detector is to be used for alarm notification only, it is not to be used as the primary smoke detector on the premises. Panic Button SR-SD SR-PB SR-PB SR-PB...
  • Page 10 Download the app Download the app • Please ensure all devices are powered and operational at this point. Download the Yale Smart Living Home App Internet Connection: Required on iOS 9 + Android 4.2 + First time registration Follow the set-up instructions in the app. Please Note: Panel Serial Number can be found on the Smart Hub sticker.
  • Page 11 Setting up devices Setting up devices • Adding new devices (Optional: Use it only if you have extra devices outside the kit) All devices in the kit are linked to the Smart Hub. If you want to add more devices, you can do this by using the “Add new device” section in the Smart Living Home App.
  • Page 12 Range Test Range Test • Check Devices Range 1.) Place each device in the location where you wish to mount them. Before mounting each device please check the system with a simple range test. Login to your Yale Home App. Go to app menu, select Settings > Alarm Settings > Tests then press the ‘Start Walk Test’ button.
  • Page 13 Mounting devices Mounting Devices • PIR Motion Detector ~1.8m 2.1m Ø 3.5mm Ø 5mm Key Pad Ø 3.5mm Ø 5mm...
  • Page 14 Mounting devices Mounting Devices • Door/Window Contact 1. The sensor should be on the frame while the magnet should be on the door/window. Testing The gap between the magnet and sensor should be no more than 10mm when closed. Test to see whether the magnet is in range of the sensor: before mounting hold the magnet and sensor in place and then pull them apart.
  • Page 15 Mounting devices Mounting Devices • PIR Camera Ø 3.5 mm ~1.8m 2.1m Ø 5 mm...
  • Page 16 Mounting devices Mounting Devices • Mounting the External Siren (21) (GB) Install ation - (I T ) Installazione - (DE) Install ation - (NO) Installasjon - (SE) Install ation - The tamper spring is fully compressed when the siren is mounted. If there is a gap, pack with a (DK) Install a tion.
  • Page 17: Mounting Devices

    Mounting devices Mounting Devices • Panic Button Smoke Detector Note: The Yale smoke detector is to be used for alarm notification only, it is not to be used as the primary smoke detector on the premises.
  • Page 18: Using The System

    Using the System Using the System • Select "fully arm" or "part arm" Changing your Key Pad PIN The Key Pad PIN is the PIN you set during the alarms first installation. You can set up to 10 sets of 4 digit PIN numbers in the app. Go to the app menu, select Settings >...
  • Page 19 Using the System Using the System • Configuring Device Behaviour Go to the app menu, select Settings > Alarm Settings > Devices to access your device list. Go in to the settings for each device and select the required setting. Setting up Part Armed Mode Part Armed mode is usually used to protect the ground floor when you are upstairs in bed.
  • Page 20: Using The System

    Using the System Using the System • Adding Alert Notifications You can add/delete email addresses that will be alerted when the alarm is triggered. You can choose to have ALL events (or Burglar only) reported via email. Hint: our report email will use the email address of: report@yalehomesystem.co.uk Save this email address as your VIP (Apple iOS) or Priority (Android) email and assign a special ringtone to it.
  • Page 21: Default Settings

    Default Settings Default Settings • Disarmed Part-Armed All devices (except PC and PVC) Burglar are pre-set to “entry” mode. Home Omit When the system is first armed, users will have 30 Disarmed Part-Armed Armed Disarmed Part-Armed Armed Burglar Burglar seconds to exit the building. If the system is already Burglar armed, triggering any sensors will cause an entry Sensor...
  • Page 22: Adding & Using Devices

    Adding & using devices Adding & using devices • Key Fob Key Pad Panic button A Panic button B Panic Learn button= Press 8 and 9 together Part Arm Away Disarm Part arm HomeArm • Use the Key Fob to remotely arm, part arm or disarm your alarm when within 30m range of your Smart Hub.
  • Page 23 Adding & using devices Adding & Using Devices • Manually requesting PIR Images During an alarm, the PIR Image Camera will send images to your phone. You can also manually request these images in the ‘control’ section of the app by pressing the image icon next to the device in the contol list.
  • Page 24 Adding & using devices Adding & Using Devices • Reset Key Pad Code Reset to factory default (0000) using the following steps: 2. Remove 1. Unscrew 3. Hold down number 3 to discharge and then insert the new battery. 4. Replace cover 5.
  • Page 25 Adding & using devices Adding & Using Devices • Smoke Detector Smoke Detection When smoke is detected the device will activate for a minimum of 10 seconds with a two tone alarm and flashing LED. Note: The Yale smoke detector is to be used for alarm notification only, it is not to be used as the primary smoke detector on the premises.
  • Page 26: Changing Batteries

    Changing Batteries Changing Batteries • Always use the correct type of batteries as replacements because any other battery type can cause problems with the operation of the system. Ensure the correct steps are taken when changing batteries in tamper protected devices. Low Battery Indicator The Hub will start to emit an intermittant beep to indicate that the batteries need changing on one of your devices.
  • Page 27 Changing Batteries Changing Batteries • External Siren Battery Change When the batteries start getting low the Siren will produce a series of audible pips and flashes when arming and disarming. Note: Take care not to confuse a low battery warning with a tamper warning. Refer to Sirens "Strobe light indication"...
  • Page 28 Changing Batteries Changing Batteries • Door/Window Contact Battery Change When the battery is low the LED will light up when the door/window is opened. Note: Door/Window Contact case tamper conditions are also indicated by a lit LED, check the tamper before changing the battery.
  • Page 29 Changing Batteries Changing Batteries • PIR Video Camer Battery Change 1. Disarm 3. Remove & 2. Unscrew replace Batteries & remove top case Key Fob Battery Change When the battery is low the LED will glow dimly when any key is pressed. The battery is changed as follows: Unscrew &...
  • Page 30 Changing Batteries Changing Batteries • Smoke Detector Battery Change When the battery is low the LED will flash accompanied by a low volume beep once every 30 seconds. 2. Remove 3.Insert Fit & rotate old batteries Rotate anti- batteries clockwise to lock. clockwise to remove Press the test button and check that the LED lights and the sounder chimes to confirm the new battery...
  • Page 31: Troubleshooting

    Troublehooting Troubleshooting • External Siren Door/Window Contact For Siren trouble shooting please refer Door/Window Contact LED lights up to the Strobe light indication chart. • Batteries are low or the tamper switch has been disturbed. Check that the tamper switch spring is making contact with the mounting surface.
  • Page 32: Troubleshooting

    Troublehooting Troubleshooting • PIR Motion Detector gives false alarms • Check pets have no access to the protected area. • Check that the PIR Motion Detector is not pointed at sources of heat or moving objects, e.g. fluttering curtains. • Check that the PIR Motion Detector is not mounted above convector heaters or pointing directly at windows.
  • Page 33: Specifications

    Specifications Specifications • All devices Power supply 2 x AA 1.5V alkaline batteries Movement detection range 110° Environmental Conditions PIR Video Camera -10°C to 40°C, relative humidity 70% non- condensing for all units except the external Siren. Alarm processing Microprocessor controlled dual Siren: -20°C to 50°C, relative humidity 95% non- edge sequential pulse count with pulse length condensing...
  • Page 34 Notes...
  • Page 35 Notes...
  • Page 36 © 2019 copyright by ASSA ABLOY All rights reserved ABN 90 086 451 907...

This manual is also suitable for:

Yale secure connect mz-8

Table of Contents