STEP 6
AVIO500 is manufactured by Nice S.p.a. (TV) IT. Nice S.p.a., in order to improve its products, reserves the right to modify their technical characteristics
at any time
ithout prior notice. In any case, the manufacturer guarantees their functionality and fitness for the intended purposes. N.B.: all technical
characteristics refer to a temperature of 20°C.
DESCRIPTION
Type
Adopted technology
Peak thrust [corresponds to the force
necessary to move a leaf]
Nominal torque [corresponds to the
force necessary to keep a leaf moving]
Speed under no load [corresponding, if
"Fast" speed is programmed]
Nominal torque speed [corresponding, if
"Fast" speed is programmed]
Maximum frequency of cycles
Maximum continuous cycle time
Operating Limits
Power supply AVIO500
Max. absorbed power
Insulation class
Emergency power supply
Flashing light output
Courtesy light
"PHOTO" input
"SbS" input
"STOP" input
Radio aerial input
Maximum cable length
Remote control possibility
ECCO5... transmitters memorised
Range of ECCO5... transmitters
Programmable functions
Self-programmed functions
Operating ambient temperature
Assembly
Protection rating
Dimensions / weight
TECHNICAL CHARACTERISTICS
Model AVIO500
DATE
Electromechanical gearmotor for automated sectional and overhead doors incorporating a control
unit complete with radio receiver for "ECCO5..." transmitters.
24V
motor, helical teeth reduction gear; drive guide with timing belt and mechanical release.
A transformer inside the motor but separated from the control unit reduces mains voltage to the
nominal voltage of 24V
used by the automation system.
[corresponds to if "Fast" speed is programmed] [0,14m/s]
The control unit allows 2 speeds to be programmed equal to approx. 100% - 60%
52 rpm [corresponds to if "Fast" speed is programmed] [0,07 m/s]
30 complete cycles per day (the control unit allows up to a maximum of 10 cycles per hour)
4 minutes (the control unit limits the continual function to 4 minutes at nominal torque)
Its structural characteristics make it suitable for use on sectional and overhead doors
with counterweights within the following parameters:
Sectional doors: max height 240 cm - max width 370 cm (8,88 m
Overhead doors: max height 280 cm - max width 350 cm (9,8 m
1 (a safety grounding system is required)
For Led visual signalling (mod. FL200)
12 V max 10 W lamp ith BA15 fitting (automotive type),
remains on for 60 s after door operation
For safety devices such as the PHR00 photocells.
For normally open contacts (the closing of the contact causes the "Step-by-Step" command)
For normally open contacts and/or for 8,2kΩ constant resistance, or normally closed contacts ith
recognition of the "normal" status (any variation from the memorised status causes the "STOP"
command)
52 Ω for RG58 or similar type of cable
Mains power supply: 30m; inputs/outputs: 20m with aerial cable preferably shorter than 5m
(observe the directions regarding the minimum gauge and type of cable)
With ECCO5... transmitters, the control unit can receive one or more of the following commands:
"Step-by-Step", "Open partially", "Open only" and "Close only"
Up to 150 if memorised in mode 1
From 10 to 50 m ithout aerial, from 50 to 100 m ith aerial incorporated in the FL200 flashing
light. The range can vary if there are obstacles or electromagnetic disturbances, and is affected by
the position of the receiving aerial incorporated in the flashing light.
"Cycle" or "Complete cycle" operation (automatic closing)
"Slow" or "fast" motor speed
The pause time in the "complete cycle" mode can be set at 15, 30, 60 seconds
The sensitivity of the obstacle detection system can be selected from 3 levels
The operation of the "Step-by-Step" command can be selected from 3 modes
Recognition of the type of STOP device (NO or NC contact or 8.2 kΩ resistance).
Automatic detection of door length and calculation of deceleration points.
9,9 Nm
[550 N]
4,95 Nm
[275N]
103 rpm
2
) max force 55 kg
2
) max force 55 kg
230V
(±10%) 50/60 Hz.
200 W
---
-20°C...+50°C
Horizontal
IP40
390 x 210 x h 130 mm / 3 kg