Download Print this page

Nice AVIO500 Instructions And Warnings For Installation And Use page 29

Advertisement

Available languages

Available languages

2.3.2 –
otocells o tional
The pair of PHR00 wall-mounted photocells, once they are connected to
the control unit, enables the detection of obstacles found on the optical
axis between the transmitter (TX) and the receiver (RX).
List of small parts for PHR00
HI LO 4X9.5 screw
3.5X25 self-tapping screw
s 5 c nylon screw anchor
4
STEP 3
The installation must be carried out by qualified and skilled
personnel in compliance with the directions provided in chapter
1 "WARNINGS".
3.1 - PRELIMINARY CHECKS
AVIO500 must not be used to po er a door that is not efficient and
safe. It cannot solve defects resulting from incorrect installation or
poor maintenance of the door.
CAUTION: incorrect installation can cause serious damage.
Before proceeding with the installation you must:
• Make sure that the door movement does not hinder roads or
public footpaths.
• After the motor has been installed, remove unnecessary cables
or chains and turn off any unneeded equipment.
4 – English
TABLE 2
Q.ty
Pcs 4
Pcs 4
Pcs 4
2.3.4 –
as er
The flashing light is controlled by the control unit and signals danger hen
the door is moving. Inside the flashing light there is also the aerial for the
radio receiver.
List of small parts for FL200
4.2X32 self-tapping screw
s 6 c nylon screw anchor
6
2.3.5 –
radio transmitter
The radio transmitter is used for the remote control of the door opening
and closing manoeuvres. It features four buttons that can all be used for
the 4 types of command to a single automation unit, or to control up to 4
different automation units.
The transmission of the command is confirmed by the LED [A]; an eyelet
[B] allows them to be hung on a keyring.
7
T1
T3
INSTALLATION
• Make sure that the weight and dimensions of the door fall with-
in the specified operating limits (Chapter 3.1.1). If they do not,
AVIO500 cannot be used.
• Make sure that the structure of the door is suitable for automa-
tion and in compliance with regulations in force.
• Make sure that there are no points of greater friction in the open-
ing or closing stroke of the door.
• Make sure that the mechanical structure of the door is sturdy
enough and that there is no risk of it derailing out of the guides.
• Make sure that the door is well balanced: it must not move by
itself when it is placed in any position.
• Make sure that the installation area is compatible with the size of
the gearmotor and that it is safe and easy to release.
• Make sure that the mounting positions of the various devices
are protected from impacts and that the mounting surfaces are
it integrated antenna o tional
TABLE 4
[A] Led
T5
T2
T4
[B]
Q.ty
Pcs 4
Pcs 4

Advertisement