3.1.3 – ist o ca les
The cables required for the installation of AVIO500 may vary depending on the type and quantity of devices to be installed; figure 13 sho s the cables
needed for a typical installation; no cable is supplied with AVIO500.
13
A
C
Table 5: List of cables
Connection
[A]
Output flashing light FLASH
[B]
Radio aerial
[C]
Input PHOTO
Note 1 – For the PHOTO, STOP and Step-by-Step cables, there are no special contraindications to the use of a single cable that groups
together multiple connections.
WARNING: – the cables used must be suitable for the type of installation; for example, an H03VV-F type cable is recommended
for indoor applications.
3.2 - PREPARING THE ELECTRICAL SYSTEM
With the exception of the plug and the power cable, the rest of the system
uses extra-low voltage (approx. 24V); the wiring can therefore be done by
personnel that is not properly qualified, provided that all the instructions in
this manual are carefully observed.
After selecting the position of the various devices (refer to figure 13) you
can start preparing the conduits for the electrical cables connecting the
devices to the control unit.
The shock-resistant conduits are designed to protect the electrical cables
and prevent accidental breakage.
Install any fixed control close to the door but a ay from moving parts and
at a height of 1.5m.
B
Cable type
Cable 2 x 0,25 mm
RG58 type shielded cable
TX = Cable 2 x 0.25 mm
RX = Cable 3 x 0.25 mm
C
Maximum length allowed
20 m
2
20 m (recommended less than 5 m)
2
20 m (note 1)
2
3.2.1 – onnection to t e lectrical
Although the connection of AVIO500 to the electrical mains is beyond the
scope of this manual, we wish to remind you that:
• The po er supply line must be laid and connected by a qualified
professional electrician.
• Have a suitably protected 16A "schuko" outlet installed, where
you can plug in AVIO500.
• Make sure that the power supply cable does not hang over mov-
ing parts or hazardous areas.
ains