08.96
5.4.1

L978 ZO determination on surface (1-point measuring cycle)

Function and application
The measuring cycle determines the actual value of a blank relative to the machine zero point.
An empirical value stored in the MDC is subsequently allowed for with the correct sign.
The multiplication factor for measurement path "2a" makes it possible to take into account the
variation range of the blanks (set value).
The probe faces the measuring surface at a distance of "a" on completion of measurement.
No automatic ZO entry is carried out or alternatively additive input of the measuring axis
difference is performed in the ZO memory specified, depending on the definition of R10.
Preconditions:
The probe must be positioned with tool offset and without G53 to face the surface to be
measured.
The following parameters must be defined prior to call:
Parameters
Description
R10 = 0
No automatic ZO entry
= 1...4
Automatic ZO entry in ZO G54...G57
= 5
Automatic ZO entry in ZO G58
R11 = 0
Without empirical value
> 0
Empirical value memory number (see Section 2.3)
R13 = 0...359.5
Compensation angle position for monodirectional probe (see Section 2.5)
R22
Probe number (see Section 2.6)
R23 = 0
ZO determination at surface
= 10
ZO determination at surface with differential measurement
R25
Variable measuring speed in mm/min
R25 = 0
Standard cycle value
R26 = 0...359.5
Start angle (with differential measurement only)
R27 = 1...R
Number of measurements at same location (typically 1..3)
max
R28 = 1...R
Multiplication factor for measurement path "2a"
max
R30 = 1...3
Number of measuring axis (see Section 2.12)
R32
Set value in relation to workpiece zero point
R36
Safe area
See Section 10.2 for result display parameters.
©