01.93
4027
Toolnose loc. < 1 or > 10 def
Explanation:
Only the following tool point directions (tool type) are permitted:
1, 2, 3, 4, 5, 6, 7, 8, 9 and 10.
4030
Safe area exceeded
Explanation:
The set/actual difference is greater than R36.
The amount of the content of the wear memory plus the compensation
value is greater than the value of NC MD 208/209.
The measurement result is not accepted.
Measuring error caused by probe
Measuring point contaminated
No tool offset has been carried out.
4031
Applicate outside tolerance
Explanation:
4032
Ordinate outside tolerance
Explanation:
4033
Applic. & ord. outside tolerance
Explanation:
4038
Meas. termination / RESET
Explanation:
Measuring error
Remedy:
Program can be continued with measurement abort signal or aborted by
pressing the RESET key.
©