5.1.3

L976 Calibrating workpiece probe in any hole (plane)

Function and application
The measuring cycle enables the probe to be calibrated in any hole, e.g. on the workpiece.
The trigger points determined are loaded automatically into the relevant MDC area.
The probe is located at the centre of the hole on completion of calibration. Where one point is
measured, the probe is located above the calibration surface by the amount "a".
Preconditions:
The probe must be called with tool offset and without G53.
The probe must be positioned to the hole centre point in the abscissa and ordinate of the
selected measuring plane and to the calibrating depth within the hole.
The following parameters must be defined prior to call:
Parameters
Description
R13 = 0...359.5
Compensation angle position for monodirectional probe (see Section 2.5)
R22
Probe type/probe number (see Section 2.6)
R23 = 2
Calibrating in any hole (plane) (see Section 2.7.5)
R25
Variable measuring speed in mm/min
R25 = 0
Standard cycle value
R27 = 1...R
Number of measurements at same location (typically 1...3)
max
R28 = 1...R
Multiplication factor for measurement path "2a"
max
R30
Measuring axis (definition depending on R23)
R31
Axial direction (definition depending on R23)
= 0
Positive axial direction
= 1
Negative axial direction
R32
Set value for calibration=diameter of hole
R33
Zero offset range
R36
Safe area
See Section 10.2 for result display parameters.
©