Initiation for transfer of measurement results
(internal call of L988)
MPF <Workp. progr.>
.
.
R39=xxxxx2xx
1)
R45=
<Measuring No.>
L <Measuring cycle>
.
.

1.9.2.4 Description of transfer parameters

When using Siemens measuring cycles, the R parameters R38 to R45 are used as transfer
parameters for logging output, protocol header information, measuring point numbers and
tolerance violations. The values stored in the R parameters are transferred and not the R
parameter numbers. This enables the R parameters to be freely chosen.
The R parameters R38 and R39 are control parameters (for Siemens measuring cycles).
The parameter addresses may have a maximum of 3 digits. The R parameter values may have
a maximum of 8 digits with additional sign and decimal point. Leading zeros in R parameters
can be ignored. In decimal-point notation, trailing zeros need not be written either.
With values less than 1, a 0 precedes the decimal point, e.g. 0.999 or 0.98.
Only negative signs are printed, positive signs are omitted. The sign is always printed in the
same column irrespective of the succeeding number of decimal places of the value to be
printed.
Control parameter R39
R39 is an 8 digit control parameter.
Configuration of R39
Digit 7
unassigned
Digit 6
unassigned
Digit 5
end of protocol
Digit 4
unassigned
Digit 3
specification of measuring point number
Digit 2
type of data to be transferred
Digit 1
modification of protocol
Digit 0
number of protocol lines of measuring point or number of space lines
_______
1)
R45 is required only if the measuring point number is preselected by the NC.
2)
R38 is transferred only if the supplementary lines are marked with * (tolerance exceeded).
©
Siemens AG 1990 All Rights Reserved
SINUMERIK 840/850/880 (BN)
1.9.2 Logging via CP315 with the SINUMERIK 840/880
L <Measuring cycle>
L988
L988
Wait until coor-
.
dination bit=0.
.
Perform mea-
suring function
Calculate mea-
L988
suring result
Transfer R39
Process R38
Transfer R38
.
.
Transfer R45
L988
Transfer channel
.
.
No.
.
Initiate transfer
6FC5197- AB70
1 Introduction
NC
PLC
Coordina-
tion bit
R39
2)
R38
1)
R45
Channel<No.>
Coordina-
tion bit
1–35

Hide quick links: