08.96
Measurement repetition
Here you enter the number of measurements at a certain measurement point.
Measurement path s
Here you enter the multiplication factor for the measurement path 2a, where a = 1 mm. If,
for example, 3 is entered, this corresponds to a measurement path of 3 x 2a = 6 mm
where, within the range 3 mm before the expected set position and 3 mm beyond it, the
probe is expected to switch on.
Store ZO in G5..
Here any input value
The results obtained from the workpiece measurement (axis coordinates) are stored in the
zero offset memories defined G54 - G57 when you press the softkey "STORE ZO".
The active input field in inverted. In addition, a text appears in the comment line bottom left.
When you have entered the required values and have pressed the key
is accepted and displayed.
8.3

Calibrating probe in any hole

This function is selected by pressing the softkey "CALIBRATE" in the "WORKPIECE
MEASUREMENT" selection display.
Prog. Para.
Sett. Data
JOG
Program reset
Workpiece measurement: Calibrating probe in any hole
W
SETPOINT DIAMETER
Calibr.
start
©
Siemens AG 1990 All Rights Reserved
SINUMERIK 840/850/880 (BN)
8 Automatic Workpiece Measurement in JOG Mode (SINUMERIK 840 SW2)
8.2 Setting the parameters for workpiece measurement and calibration
from 4 ˆ =
G54
to 7 ˆ =
G57 is permissible.
Data I/O
Program.
L
D
6FC5197- AB70
Diagnostic
Mode grp.: 1
Channel : 1
D/L
R32=
Meas. type
R23 =
Plane
TRIGGERING POINTS:
ABSCISSA: - DIRECTION 0
ABSCISSA:+ DIRECTION 0
ORDINATE: - DIRECTION 0
ORDINATE:+ DIRECTION 0
APPLICATE: - DIRECTION 0
APPLICATE:+ DIRECTION 0
Plane
Drilling axis
, the value
User
40
8–5