Call Waiting (Cw) - Intracom netMod User Manual

Isdn network termination unit
Table of Contents

Advertisement

User's Manual of netMod Network Termination Unit
By using AT Commands, MSN numbers are assigned on the data port (RS232 or USB).
Type:
at&ziN= MSN number, to assign an MSN number on the data port
The number N takes the values:
N=6, for the first MSN port number
N=7, for the second MSN port number
N=8, for the third MSN port number
at&ziN= Enter key, to delete a previously assigned MSN number on the data port (N=6 or
7 or 8)
To view the MSN numbers assigned on both analogue ports (ab1 and ab2) and the data
port type:
at&zi?
Note that the above settings, initiated by AT Commands are
permanently stored in netMod's memory.
2.

Call Waiting (CW)

Using AT Commands write the proper values in the S79-Register to activate / deactivate
the supplementary services on each of netMod's analogue port (ab1 or ab2).
ATS79=0 deactivates the service on both analogue port ab1 and ab2
ATS79=4 activates the service on the analogue port ab1 and deactivates the service on
the analogue port ab2
ATS79=8 deactivates the service on the analogue port ab1 and activates the service on
the analogue port ab2
ATS79=12 activates the service on both analogue port ab1 and ab2
Note that this service is initially activated on both analogue ports
of netMod.