Figure 20 Host Interface Ports (Eternus Af150 S3/Af250 S3); Table 16 Status And Meaning Of Each Led (Host Interface For The Eternus Af150 S3/Af250 S3) - Fujitsu ETERNUS AF S3 Series Basic Operation Manual

All-flash arrays
Hide thumbs Also See for ETERNUS AF S3 Series:
Table of Contents

Advertisement

A. Component Names
Controller Enclosure
Host Interface
A host interface is a board that has interface ports to connect a controller to the server.
ETERNUS AF150 S3/AF250 S3
There are five types of host interfaces: FC 32Gbit/s, FC 16Gbit/s, iSCSI 10Gbit/s (10GBASE-SR/10GBASE-CR),
and iSCSI 10Gbit/s (10GBASE-T).
Figure 20
FC 2 ports
iSCSI 10Gbit/s (10GBASE-SR)
LINK/FAULT LED
iSCSI 10Gbit/s (10GBASE-CR) (for
Copper Twinax cable connection)
LINK/FAULT LED
The LEDs turn on or blink to indicate the statuses that are listed below.
Table 16
Status and Meaning of Each LED (Host Interface for the ETERNUS AF150 S3/AF250 S3)
LED name
LINK/FAULT
FAULT
LINK
Host Interface Ports (ETERNUS AF150 S3/AF250 S3)
FC 4 ports (only for ETERNUS AF250 S3)
LINK/FAULT LED
iSCSI 10Gbit/s (10GBASE-T)
LINK/FAULT LED
LED status
(green)
(amber)
(green)
(amber)
Meaning
The link between the host interface port (FC) and the
destination port has been established.
The host interface port (FC) is in error status.
The link between the host interface port (iSCSI) and the
destination port has been established.
The host interface port (iSCSI) is in error status.
79