Off-Premises Or Out-Of-Building Stations; Off-Premises Connections - Avaya S8700 Installing Manual

Media server with media gateway
Hide thumbs Also See for S8700:
Table of Contents

Advertisement

3
Connect an A25D cable between the sneak fuse panel and the terminal block connector
associated with the green row in the previous step.
Install a green label on the terminal block to identify the remote location.
4
5
Administer per the Administrator's Guide for Avaya MultiVantage Software.

Off-Premises or Out-of-Building Stations

Out-of-building campus stations are telephones not physically located in the same building as
the equipment room but located on the same property. Only analog telephones connected to
TN746B, TN769, or TN2183 Analog Line circuit packs can be installed out-of-building.

Off-Premises Connections

''Connections for 1 to 8 Out-of-Building Analog Telephones'' on page 158
connections for 1 to 8 off-premises analog telephones.
''Connections to 24 Out-of-Building Telephones'' on page 159
24 off-premises analog telephones. Concentrations of analog line pairs are used at both
buildings to minimize the off-premises wiring required. At the MDF, jumpers must be
connected between 1 row/connecting block in the white field and up to 3 rows/connecting
blocks in the purple field. At the station location, a WP-90929, List 1 Concentrator Cable is
used. There are 8 station appearances on each of the 3 fingers of the concentrator cable.
The maximum distance from the media gateway to the out-of-building telephone is 6000 feet
(1829 meters) using 24 AWG (#5) (0.5 square millimeters) wire.
The maximum range of out-of-building analog telephones (500-, 2500-, or 7100-types)
connected to an analog line circuit pack should be such that the maximum loop resistance does
not exceed 1300 ohms.