Connecting To The Zt-20Xx-Iog Module (Init) - ICP DAS USA ZT-257 Series Quick Start Manual

Dio data concentrator
Table of Contents

Advertisement

3.1.2. Connecting to the ZT-20xx-IOG Module (INIT)

Step1 Configure the ZT-2570 module to establish a common ZigBee network
with the ZT-20xx-IOG module
In order to create a connection between the ZT-2570 module and the ZT-20xx-IOG
module, configure the ZT-2570 module using the settings indicated in the table below.
See Section
3.2 Configuring the ZT-257x Module
ZT-2570 module.
After completing the configuration, set the DIP switch on the ZT-2570 module to the
ZBRUN position, and then reboot the module.
Parameter
Pan ID
(ZigBee Group ID)
Node ID (*)
RF Channel (*)
Application Mode (*)
Data Format
Baud Rate
Note that the Pan ID must be the same for all modules that exist in the same ZigBee network.
(*): See item2 in step 2 below.
Step2 Configure the ZT-20xx-IOG module via the ZT-2570 module
Set the DIP switch on the ZT-20xx-IOG module to the "INIT" position (i.e., move DIP
switch 1 to the ON position).
Configure the ZT-20xx-IOG module, and then adjust the hardware switches based on
Node ID, RF Frequency and Application Mode
See Section
3.1.3 Hardware Settings for the ZT-20xx-IOG Module
adjust the ZT-20xx-IOG module.
ICP DAS, ZT-257x DIO Data Concentrator Quick Start Guide, v1.0
ZT-20xx-IOG
INIT
0x3FFF
ZigBee Router
0x0020
Set using the Rotary switch (0 - F)
Level Mode
N/A
N/A
Copyright © 2016, by ICP DAS Co., LTD. All Rights Reserved
for details of how to configure the
ZT-2550
ZT-2570
Set to the same ID as the
ZT-20xx-IOG
ZigBee Coordinator
0x0000
Set to the same frequency as
the
ZT-20xx-IOG
Transparent Mode
None, 8, 1
115200 bps
settings indicated in the table above
for details of how to
ZT-USBC
N/A
the
.
Page 17