Logger Operation; Recording With Memory Cleared; Recording With A Partial Or Full Memory - AEMC Simple Logger II Series User Manual

Trms clamp-on, ac current, ac voltage, dc current, dc voltage, thermocouple, temp/rh, event logger
Hide thumbs Also See for Simple Logger II Series:
Table of Contents

Advertisement

Find Quality Products Online at:
4.8

Logger Operation

When the instrument is in STANDBY mode, the following occurs (provided
there is sufficient battery voltage and no data is stored in the instrument's
memory):
The GREEN LED single-blinks every 5 seconds. (STANDBY
mode is active and the logger is not recording).
The RED LED is OFF, indicating there is no data in memory.
The PRESS button is used to Start/Stop a Recording Session.
If the PRESS button is not pressed for a period of one minute,
the instrument will enter SLEEP mode and wait for either another
button press or the recording start time to arrive (if a recording is
scheduled). While in SLEEP mode, the LEDs will not blink.
A button press of 0.5 second will return the unit back to the normal
STANDBY mode.
4.8.1

Recording with Memory Cleared

When a recording starts, the logger will continue to record until one of the
following occurs:
The session is complete.
The memory is full and the recording mode is Start/Stop or Alarm.
The PRESS button is pushed until the STOP (ORANGE) LED
lights up and is released before the next LED lights.
The Stop Recording command from the Simple Logger II Control
Panel is sent to the unit.
The battery voltage falls below 1.7V.
4.8.2

Recording with a Partial or Full Memory

If the RED LED is double-blinking every 5 seconds, the memory is full and
must be erased before any further recording can be performed.
If the RED LED is single-blinking every 5 seconds prior to starting a new
recording session, the memory is partially full.
To save, clear, or check memory availability, use the Simple Logger II Con-
trol Panel software.
There may be instances where the GREEN LED is also double-blinking
every five seconds indicating that the logger is still recording. The user
can choose to stop the recording session and download the session and/
or erase the memory.