AEMC Simple Logger II Series User Manual page 22

Trms clamp-on, ac current, ac voltage, dc current, dc voltage, thermocouple, temp/rh, event logger
Hide thumbs Also See for Simple Logger II Series:
Table of Contents

Advertisement

Find Quality Products Online at:
MODEL
ELECTRICAL
Channels
Connection
Input
Input Level
0 to 1V (for use with current
probes with a voltage output)
Accuracy
(50/60Hz)
±(0.5% of Reading + 1mV)
±(0.5% of Reading + 0.5mV)
Resolution
Maximum Input Voltage***
Input Impedance
Sample Rate
Storage Rate
Storage Modes
Recording Length
Memory
240,000 measurements (512KB). Recorded data is stored in non-volatile
Communication
Power Source**
Battery Life
100 hours to >45 days (dependent on storage rate/recording length)
MECHANICAL
Dimensions
Weight (with battery)
Case
Vibration
Shock
Drop
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
SAFETY & ELECTRO-MAGNETIC COMPATIBILITY
Safety Rating
Protection Degree
Electro-Magnetic
EN 61326-1; 07/1997 (+A1 10/1998, +A2 09/2001, +A3 05/2004)
Compatibility
CE Approved
Simple Logger
®
II Series
GlobalTestSupply
www.
L562
Two
Current Channel
BNC
Two recessed banana jacks
0 to 10mV unspecified
10 to 50mV:
±(0.5% of Reading + 1V)
50 to 1000mV:
±(0.5% of Reading + 0.5V)
0.1mV
5Vrms or ± 7.07V
PEAK
800kW
64 samples/cycle
Programmable from 125ms to 1 per day
Start/Stop, FIFO and Extended Recording Mode* (XRM
15 minutes to 8 weeks, programmable using DataView
memory and retained even if battery is low or removed.
USB 2.0 optically isolated
2x1.5V AA-cell alkaline batteries
5.38 x 2.75 x 1.28" (136 x 70 x 32mm)
6.4 oz (180g)
UL94-V0
IEC 68-2-6 (1.5mm, 10 to 55Hz)
IEC 68-2-27 (30G)
IEC 68-2-32 (1m)
14° to 122°F (-10° to 50°C)
-4° to 140°F (-20° to 60°C)
Up to 85% at 95°F (35°C), Non-condensing
6562' (2000m)
EN61010-1; 600V CAT III, 300V CAT IV; Pollution Degree 2
IP40
Yes
.com
Voltage Channel
0 to 600V
AC
0 to 5V unspecified
5 to 50V:
50 to 600V:
0.1V
1.2 x 600V
40MW
), Alarm
®