Disposal Of The Selector - Nakanishi E3000 SELECTOR Operation Manual

Hide thumbs Also See for E3000 SELECTOR:
Table of Contents

Advertisement

Trouble
Motor speed is not
displayed correctly.
Not change motor
rotation direction.
Motor stops during
rotation.
*Refer to P82 " 18 SETTING OF OPERATIONG PARAMETERS " section of the E3000 CONTROLLER.

16 . DISPOSAL OF THE SELECTOR

When disposal of a SELECTOR is necessary, follow the instructions from your local government agency for proper
disposal of industrial components.
58
Cause
Motor Fixed Speed is set in the
parameter.
Motor Maximum Speed is set in the
parameter.
Air Input Monitoring Override is set in the
parameter and the motor's maximum
speed is limited to 30,000 min
Motor spindle (motor speed of the
-1
80,000min
(rpm)) is connected to the
SELECTOR and
parameter is set
.
Not using the Communication Cable.
(LINK LED ⑲ does not illuminate.)
Control Mode is set to AUTO. (The Control
Button (CTRL) is set to AUTO)
Not using the Communication Cable
(LINK LED ⑲ does not illuminate.)
Load level too high.
Low air pressure (The Error Code " E7 " is
displayed on the Digital Speed Indicator of
the E3000 CONTROLLER).
Inspection / Corrective Action
Release parameter
" 18 - 3 ③
section of the E3000 CONTROLLER
Operation Manual.)
Release parameter
P85 " 18 - 3 ④
Motor Speed " section of the E3000
CONTROLLER Operation Manual.)
Release parameter
motor speed, by supplying the cooling air
-1
(rpm).
into the motor spindle. (Refer to
P86 " 18 - 3 ⑦
Monitoring Override " section of the E3000
CONTROLLER Operation Manual.)
Set
" 18 - 3 ⑧
Control Voltage / DC+10V Signal Method "
section of the E3000 CONTROLLER
Operation Manual.)
Use the Communication Cable.
Set the control mode to MANUAL. (The
Control Button (CTRL) is set to MANUAL
on the control panel of the E3000
CONTROLLER.)
Use the Communication Cable.
Check the Load monitor LED Ⓖ and
control motor speed. (Refer to Fig. 23)
Adjust to the air pressure 0.35MPa
(50.8psi).
. (Refer to P84
Setting Fixed Motor Speed "
. (Refer to
Setting Maximum
. Set the desired
Selection of Air Input
Parameter
. (Refer to P86
Selection of Motor Speed

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne212

Table of Contents