Nakanishi E3000 SELECTOR Operation Manual page 25

Hide thumbs Also See for E3000 SELECTOR:
Table of Contents

Advertisement

Pin
Code
Function
No.
Motor Select 0
17
SEL0
Speed Point
Select 0
External
Power Source
18
COM_2
for External
Output
19
PULSE
Rotating Pulse
20
WARNING WARNING
Speed
21
COIN
Achievement
22
Not used
Motor Speed
23
VR
Control
Voltage
Torque Load
24
LOAD
Monitor
Rotating
Speed Analog
25
SPEED_V
Monitor
Voltage
52
Input /
Output
Input
Input
DC0V or DC+24V
Output 1 pulse / rotation
' OFF (Open) ' :
Normal Operation
Output
' ON (Closed) ' :
Warning
' OFF (Open) ' : Set
speed not achieved
Output
' ON (Closed) ':
Set speed achieved
-1
Speed (min
(rpm)) =
Motor Speed
Input
Control Voltage
(VR) x 10000 /1.5
0V ≦ VR ≦ 10V
Torque Load
Monitor (%) =
Output
Torque Load Monitor
Voltage x 20
-1
Output 10,000min
(rpm) / V
Description
Use when selecting motor, after connecting
CONTROLLER to the SELECTOR.
4 motors can be selected by SEL0 and
SEL1 combination. (Refer to P69 "15 - 2 -
2 (7) Motor Selection Table. 4 of the E3000
CONTROLLER Operation Manual.)
Note : When Connecting the
CONTROLLER to the SELECTOR,
"Speed Point Select 0" can not be
used.
Power source to be used for External outputs
Signals.
1 revolution of the motor generates one pulse.
Duty 50%.
Output shows that warning has occurred.
Warning code will be displayed on Digital
Speed Indicator of the E3000 CONTROLLER.
Shows that the Motor has achieved more than
90% of the set speed.
*Note : Never use a pin labeled not used.
Sets rotating speed of motor. (For motors
-1
except 80,000min
(rpm) of motor)
-1
When using 80,000min
Setting parameter
. (Refer to P86 "18 - 3
Selection of Motor Speed Control
Voltage / DC+10V Signal Method" section of
the E3000 CONTROLLER Operation Manual.)
Refer to P56 "Fig. 31, 32" about relationship
between Motor Speed and Motor Speed
Control Voltage (VR).
Shows that the torque being applied to the
analog motor.
20% / V 100% (rating) / DC+5V
Torque Load Monitor : 0 - 200%
(0V ≦ LOAD ≦ 10V)
Output the rotation speed of rotating motor
with Analog Monitor Voltage.
-1
10,000min
(rpm) / V  0V ≦ SPEED_V ≦ 10V
(rpm) of motor speed.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ne212

Table of Contents