8 . REPLACING THE FUSES

WARNING
Before removing the fuse holder and fuses, be sure that the Main Power Switch ⑭ is turned OFF
and remove the Power Cord has been removed from the SELECTOR.
Verify type and use only following the properly rated and type of fuse.
Speci¿ ed fuses : T1.6AL (250V)
* Failure to use the proper type and rated fuse will result in ¿ re, injury, electric shock and / or
product damage.
(1) Push on the clips on the right and left of the fuse holder and remove the fuse holder block.
(2) Remove the bad fuse or fuses and replace with the proper type and rating of fuse by the input voltage being
used.
(3) Replace the fuse holder containing the fuses into the Main Power Inlet with Power Supply Fuses ⑮ and verify
it snapped in place.
9 . BRACKET AND RUBBER PAD INSTALLATION
9 - 1 Installation of the Bracke
CAUTION
If there is a possibility for the SELECTOR from its mounting location, be sure to secure it with
the provided Brackets for safety.
When installing the SELECTOR, be sure to protect the SELECTOR (air joints and other
connectors) from cutting oil, mist oil, powder dust, other contaminants that can buildup heat
and damage to the internal components of the SELECTOR.
The Bracket can be installed on the " Bottom Mounting (Fig. 6) " and on the " Rear Mounting (Fig. 7) " of the SELECTOR.
(1) Attach the Installation Brackets (2pcs.) using the provided mounting screws (4pcs.).
(2) Attach the SELECTOR (Bracketʼs Slotted Area) to the machine using the provided mounting screws.
Bottom Mounting
40
Slotted Area
Bracket
Fig. 6
Cap
Fig. 5
Rear Mounting
Slotted Area
Bracket
Fig. 7

Hide quick links: