Pin
Code
Function
No.
6
RUN
Rotating
Rotating
7
DIR_OUT
Direction
8
ERR
Error
Not used
9
Internal GND
for Motor
10
GND
Speed Control
Voltage
Internal Power
Source for
11
Vcc
Motor Speed
Control
Voltage
Motor Current
12
MOTOR_I
Monitor
Internal GND
13
GND
for Analog
Monitor
Rotate
14
START
Command
UP / DOWN
Signal for
15
UD_IN
Setting Motor
Speed
Rotates Motor
-1
500min
16
at "Centering"
(rpm)
speed
Input /
Output
' OFF (Open) ' :
Stop
Output
' ON (Closed) ' :
Rotating
' OFF (Open) ' : FWD.
Output
' ON (Closed) ' : REV.
' OFF (Open) ' :
Error
Output
' ON (Closed) ' :
Normal
Internal
Output
CONTROLLER
GND
Internal Power
Output
Source : DC+10V
2Amp / V,
Output
0V ≦ MOTOR_I ≦ 10V
Internal
Output
CONTROLLER
GND
' OFF (Open) ' :
Stop
Input
' ON (Closed) ' :
Start
' OFF (Open) ' :
Speed Down
Input
' ON (Closed) ' :
Speed Up
' ON (Closed) ' :
-1
500min
(rpm)
Input
' OFF (Open) ' :
Normal Operation
Description
Output shows that the motor is rotating.
Output shows the direction of the Motor is
rotating.
Output shows that error has occurred. Error
code will be displayed on Digital Speed
Indicator of the E3000 CONTROLLER.
When setting parameter
Mode can be changed. (Refer to P84 "18 - 3 ①
Setting of Error Output Mode" section of
the E3000 CONTROLLER Operation Manual.)
*Note : Never use pin labeled not used.
This GND will be used for "Motor Speed
Control Voltage (VR)".
Internal Power Source for "Motor Speed
Control Voltage (VR)".
Output Motor Current Monitor with Analog
Monitor Voltage.
2Amp / 1V. Max. 20Amp.
This GND will be used for analog monitor
(MOTOR_I, SPEED_V, and LOAD).
Motor Start and Motor Stop Signal
Setting parameter
, can start with
forward rotation. (Refer to P86 "18 - 3 ⑥
Selection of External Motor Start
Signal Control Mode" section of the E3000
CONTROLLER Operation Manual.)
Determines speed up or speed down.
Need to set parameter
P85 "18 - 3 ⑤
Selection of External
Speed Control Mode" section of the E3000
CONTROLLER Operation Manual.)
Set motor rotation speed is 500 min
Use the Centering Mode.
, Error Output
. (Refer to
-1
(rpm).
51