ESAB Mig 4004 iMV User Manual And Spare Parts page 39

Multiprocess inverter for welding with high performance
Table of Contents

Advertisement

Available languages

Available languages

Inductance -
inductance in the welding MIG / MAG. Lower inductance produces a harsher sound
but a stable, concentrated arc. Higher inductance results in a wider weld pool and
less spatter.
12) Led indicator function Hotstart.
13) Led indicator function Arcforce.
14) Led indicator function Inductance.
15) Button
- memory selector 1 - the welding data memory has a back-up so that
the settings remain even if the mains supply has been switched off. Press button for 5
seconds to store the welding data in the memory. The welding data is stored when
the green indicator lamp starts to flash.
16) Button
- memory selector 2 - the welding data memory has a back-up so that
the settings remain even if the mains supply has been switched off. Press button for 5
seconds to store the welding data in the memory. The welding data is stored when
the green indicator lamp starts to flash.
17) Potentiometer for adjusting the welding current in TIG and Stick electrode process,
for adjusting the welding voltage in the MIG/MAG process or % for Hotstart, Arcforce
or Inductance.
WARNING
5.2 Stick electrodes operation
1)
C
onnected
Origo 4004 iMV
2)
C
onnected the electrode holder cable and the
polarity required by the type of electrode.
3)
Set the I/O switch to the I position. The pilot led lights.
4)
Select the process stick electrode.
5) Select the type of electrode that will be used.
6) Enable and adjust or disable the functions Hotstart and Arcforce as desired.
7 Pre-set the welding current throught the potentiometer or the remote control.
)
8) Start the welding scratching the electrode in the workpiece for start the arc and
readjust the current, if necessary.
when selected this feature to its regulation amends the
Prior to welding, it is imperative that proper protective clothing
(welding coat and gloves) and eye protection (glasses and/or welding
helmet) be put on. Failure to comply may result in serious injury.
to the main power supply
.
work clamp
- 39 -
cable
according to the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Origo 4004i mv

Table of Contents