4. Installation
4.9.8. Connecting the DHW tank sensor/
thermostat
Ws
DHW sensor
Connect the DHW tank sensor or thermostat to the
Tdhw terminals of the connector.
4.9.9. PC/Laptop connection
A PC or Laptop can be connected to the telephone
connector using the optional Recom interface. Using
the Recom PC/Laptop service software, you can enter,
change and read out various boiler settings.
4.9.10. Shutdown input
The boiler has a shutdown input. This input is on the BL
terminals of the connector.
CAUTION
Only suitable for potential-free contacts.
i
For use of this input remove the jumper cable
The behaviour of the input can be changed using
p 36.
See chapter: "Parameter descriptions", page 76
58
MCA Pro 45/65/90/115
On/off
OT
BL
RL
Tout Tdhw
On/off
OT
BL
RL
MCA-Pro ISM Rv.4.1 2/2017
Ws
X13
Tout
Tdhw