17. ELECTRICAL CONNECTIONS
This machine is only electrically safe if it is correctly connected to an ef cient earth system in compliance with current
safety regulations.
Connect the boiler to a 230V single-phase earthed power supply using the supplied three-pin cable, observing correct
LIVE-NEUTRAL polarity.
Use a double-pole switch with a contact separation of at least 3 mm. When replacing the power supply cable, t a
2
harmonised HAR H05 VV-F' 3x0.75mm
cable with a maximum diameter of 8 mm.
...Access to the power supply terminal block
The 2A fast-blowing fuse is incorporated in the power supply terminal block (to check and/or replace the fuse, pull out
the black fuse carrier).
IMPORTANT:
respect polarity L (LIVE) -N (NEUTRAL).
(L) = Live (brown)
(N) = Neutral (blue)
= Earth (yellow-green)
(1) (2) = Contact for room thermostat
Figure 9
18. CONNECTING THE ROOM THERMOSTAT
INSTALLATION INSTRUCTIONS