General Information; Gas Type; Additional Requirements; Factory Tests - DeDietrich MCA Pro 45 Installation And Service Manual

Wall-hung gas-fired condensing boilers
Table of Contents

Advertisement

1. Introduction
1.3 General informatio

1.3.1. Gas type

Gas type
Supply pressure (operating)
Natural gas
3.5 -14"w.c./ 8.7 - 35 mbar
Propane
8 - 13"w.c./ 20 - 32.5 mbar

1.3.2. Additional requirements

Apart from the legal provisions and codes, the
additional requirements described in these instructions
must also be observed.
For all provisions and requirements referred to in these
instructions, it is agreed that all addenda or subsequent
provisions will apply at the time of installation.
WARNING
Installation of the appliance must be done by a
qualified installer in accordance with prevailing local
and national regulations.
1.3.3. Factory test
Before leaving the factory, each boiler is set for
optimum performance and tested using natural gas and
checked for the following items:
Electrical safety
Adjustment (CO
)
2
Water tightness/Leaks
Gas tightness/Leaks
Parameter settings
The boiler has not being tested in the factory before
shipment using propane. Installers are required to alter
gas valves on certain models and check combustion
using a combustion analyser if propane to be used
MCA-Pro ISM Rv.4.1 2/2017
MCA Pro 45/65/90/115
13