6. Use the UP and DOWN buttons to point to "Somfy
485 Node Discovery".
7. Press OK to enter the selection.
8. Once the node ID appears on the screen, press
OK again.
9. Use the directional buttons to navigate to "Down
Limit Setting" and press OK to enable setting the drop.
10. Use the UP and DOWN arrows to adjust the screen
drop to the desired amount, up to MAX DROP to
the bottom of the cassette.
DO NOT set the drop more than MAX DROP.
Doing so can damage the screen material.
11. Once the viewing area is positioned and the drop
is correct, press the OK button to save the new
lower limit and drop.
12. Turn the setting tool off.
13. Disconnect the 485 cable from the Setting Tool.
14. Reconnect the 485 cable to the control system.
Programming AC(110v) 485 - with Limit Setting Tool
CONTROL AC(110v) 485 WITH
3RD PARTY - VIA SERIAL
There are several options to control a Solo 2 485
screen with 3rd party controls. To integrate with your
preferred solution see the corresponding programming
guide and/or the system manufacturers instructions.
Note: To change the programming (lower limit) you
will need either a SIFI or an 485 limit setting tool.
• For connection to your control system refer to pinout
image (pg 22). Then use your control system's
programming guide to send commands to control
the screen. For further integration help call support
at 512.832.6939.
485 Serial Conductors (refer to pg 5)