Screen Innovations Solo 2 Installation Instructions Manual

Screen Innovations Solo 2 Installation Instructions Manual

Hide thumbs Also See for Solo 2:

Advertisement

Quick Links

Solo / Pro 2
Installation Instructions
110v AC Motors

Advertisement

Table of Contents
loading

Summary of Contents for Screen Innovations Solo 2

  • Page 1 Solo / Pro 2 Installation Instructions 110v AC Motors...
  • Page 2 Please use these QR Codes to access the updated installation instructions and video tutorials. Solo 2 Solo Pro 2 Thank you for purchasing an SI product. If you have any questions or need any assistance with your Solo/Pro 2, we would love to help you.
  • Page 3: Table Of Contents

    CONTENTS Initial Consideration ............. Parts in the Box - AC(110v) RTS ....... Parts in the Box - AC(110v) 485 ....... Spacer Blocks and Leveling Shims ......Pre-wire - AC(110v) 485 ..........Installation ..............6 - 14 Flatten the material at the weight bar...... Pairing another RF Remote ........
  • Page 5: Initial Consideration

    INITIAL CONSIDERATIONS Thank you for your purchase of Solo/Pro 2. The screen is mountable outdoors, but is not waterproof. It has not been designed to be run or left in the rain or condensing humidity. Also avoid water spray, splash and extreme heat or cold.
  • Page 6: Parts In The Box - Ac(110V) Rts

    AC(110v) RTS Parts in the box Solo/Pro 2 screen (6) Leveling Shims (6) Wood fasteners RF Remote (2) Ceiling/Wall Locking brackets AC(110v) RTS - Parts in the Box...
  • Page 7: Parts In The Box - Ac(110V) 485

    AC(110v) 485 Parts in the box Solo/Pro 2 screen RJ45 coupler and bracket (2) Ceiling/Wall Programming Kit Locking brackets Additional accessories required for 485 (6) Wood control (pg. 34) (6) Leveling Shims fasteners AC(110v) 485 - Parts in the Box...
  • Page 8: Spacer Blocks And Leveling Shims

    SPACER BLOCKS & LEVELING SHIMS Spacer Blocks are used to Leveling Shims are used if clear an obstruction on the the ceiling or other wall. Connect spacer block mounting surface is out to each wall bracket before of level or plumb. Connect installation.
  • Page 9: Pre-Wire - Ac(110V) 485

    PRE-WIRE - AC(110v) 485 1. Run Cat5e cable to the left side of screen cassette installation location (refer to pg. 9). 2. Terminate the wires with the provided pinout as shown below or use the incl. coupler to extend the cable upto 200'.
  • Page 10: Installation

    INSTALLATION Proper mounting preparation will ensure a great installation. Mounting brackets must be level to each other, as well as plumb. They must be screwed into structural members of some kind, such as ceiling joists or wall studs. You may use the wood screws provided, or other anchors (not provided) capable of carrying the load, that is suitable to the substrate.
  • Page 11 Medium Large 2.02” 3.43” 3.43” 2.01” (51mm) (87mm) (87mm) (51mm) Bracket 4.88” 3.78” size (124mm) (96mm) Drop View Height " Solo/Pro 2 - Installation...
  • Page 12 2. Determine the desired horizontal viewing position centerline of the projected viewing area. 3. The Solo/Pro 2 screen must be installed with the brackets no more than 4 inches from each end of the cassette. Measure the overall length of the cassette to determine the min.
  • Page 13 Cassette Length Brackets secured to Wall or wire Ceiling Structural Supports exits back 1" Min to 4" Max corner of the cassette pull wire through the hole in gray zone View Width Screen Centerline Structural Supports Solo/Pro 2 - Installation...
  • Page 14 4. Secure the brackets to the wall or ceiling structural supports using appropriate fasteners. Make sure the brackets are along the same level line. Install the terminal block bracket (485 only) next to the left bracket. This bracket is used to hold the power and/ or controls terminal block easily out of sight.
  • Page 15 5. Ensure the wall bracket lever is down. Proper position for installing screen 6. Push the power wire into the pre-wire hole Follow local electrical codes when running and terminating AC(110v) wires. Solo/Pro 2 - Installation...
  • Page 16 7. Connect the screen terminal block to the data pre- wire terminal block. Then press the connected terminal block into the mount. Data Power Solo/Pro 2 - Installation...
  • Page 17 8. Hang the screen on the mounting brackets ensuring that all hooks are engaged in the channel in the back of the cassette for all the brackets. Hanging the screen, will require 2 people. Solo/Pro 2 - Installation...
  • Page 18 9. Slide the cassette left to right to verify it is positioned at your desired viewing location, then lock the screen in place, rotating the wall bracket lever to the upward position. 10. Remove the weight bar screw before deploying screen (see red label on the weight bar) 11.
  • Page 19: Flatten The Material At The Weight Bar

    FLATTEN THE MATERIAL AT THE WEIGHT BAR Follow these steps: 1. Bump the bottom of the weight bar up several times along it. 2. Use 2 fingers to pinch the material just above the middle of the weight bar and lightly pull on the material to smooth out any wrinkles at the weight bar.
  • Page 20: Pairing Another Rf Remote

    PAIRING ANOTHER RF REMOTE USING ORIGINAL REMOTE If another remote was purchased, it will not come paired to your screen motor. To pair it, first take the working remote supplied with the Solo/Pro 2 and press the Program button on the back of the remote until the screen jogs once.
  • Page 21: Motor Commissioning Guide Ref

    MOTOR COMMISIONING GUIDE Based on your order, refer the motor (485/ RTS) your screen uses. Scan the QR code, alternately use the link below to access https://files.screeninnovations.com/ Downloads/Programming+Guides/ quick-motor-commisioning-guide.pdf Commisioning Guide Reference...
  • Page 22: Control Guide Ref

    CONTROL GUIDE REF With your screen order, you shall receive one of the below mentioned Controls Guides which will walk you through integrating with control system. Fontus Screen Control Guide (Dry Contact, 12v Trigger, IR): Scan the QR code, alternately use this link to access https://files.screeninnovations.com/ Downloads/Installation+Instructions/...
  • Page 23 TRO.Y Installation Instructions (RS232, IP Control, 3rd party Control system): Scan the QR code, alternately use this link to access https://files.screeninnovations.com/ Downloads/Installation+Instructions/ Connectivity/troy-installation-instructions.pdf LinkPro Z Installation Instructions (IP Control, 3rd party Control system): Scan the QR code, alternately use this link to access https://files.screeninnovations.com/ Downloads/Installation+Instructions/...
  • Page 24: Mounting Accessories

    MOUNTING ACCESSORIES (purchased separately) Zero Gap Wall Brackets Décora Ceiling Brackets Décora Flying Brackets Ceiling/Wall Locking Brackets (incl. standard) Mounting Accessories...
  • Page 25: Motor Accessories Ac(110V) Rts

    MOTOR ACCESSORIES - AC(110v) RTS (purchased separately) LinkProZ Connect Solo remote TaHoma Motor Accessories - AC(110v) RTS...
  • Page 26: Motor Accessories Ac(110V) 485

    MOTOR ACCESSORIES - AC(110v) 485 (purchased separately) SOMFY Data Hub 1870262 Bus Power Supply Data Hub Bus Power Supply BACK OPEN PRESET 1 STOP PRESET 2 LIGHT PRESET 3 CLOSE Limit Setting Tool STOP Decoflex Wall Switch SIFI Motor Accessories - AC(110v) 485...
  • Page 27: Storage And Transport

    STORAGE AND TRANSPORT Before storing or transporting Solo/Pro 2, make sure the screen is fully retracted. Disconnect the motor power supply and any control wiring to make sure the screen does not deploy. Failing to do so may damage the screen. Make sure to put the shipping locks back on.
  • Page 28 3. Repeat the process to move the material from the center toward the other edge. 4. If the screen has been stored in a wrinkled condition. The wrinkles may not fall out immediately. If wrinkles remain after an hour, call 512.832.6939 (opt.1) for further instructions.
  • Page 29: Care And Maintenance

    CARE AND MAINTENANCE DO NOT scrub the screen material. This will damage the viewing surface. These screens are designed and engineered to be virtually maintenance free. There are no user serviceable parts inside, except for the screen material. The screen needs to be kept clean - free of dust, dirt, hair, particles, and any other foreign material.
  • Page 30: Troubleshooting

    TROUBLESHOOTING Solo/Pro 2 is 100% programmed and tested at the factory. In case of a malfunction please use the troubleshooting guide table. Symptom Possible Cause Solution Screen No power to the Check for 120V at motor. won't run power connection and/ check breaker box.
  • Page 31 Tech Support: 512.832.6939 Symptom Possible Solution Cause For RTS Remote too far Move to within 30 ft. away of Solo Remote orientation Hold remote vertical RF interference Turn off other sources of RF RF Shielding Move to position where metal objects, RTS won't wiring, or foliage does operate...
  • Page 32 Tech Support: 512.832.6939 Symptom Possible Solution Cause For 485 Incorrect or Check the wire pinouts poor cable and termination. Look termination. for broken, loose, or damaged wires. Reterminate if necessary. via SIFI RS 485 SIFI is not Check that the green won't operate powered.
  • Page 33 Tech Support: 512.832.6939 Symptom Possible Solution Cause RS 485 SIFI is Use the service keypad (if won't not on available) to validate the operate the local 485 network and motors (cont.) network. are operating properly before troubleshooting SIFI network problems. Check that the SIFI is communicating on the local network.
  • Page 34: Warranty

    Changes or modifications not expressly approved by the manufacturer could void the user's authority to operate the equipment. Solo/Pro 2, the Solo wordmark, and the Screen Innovations logo are registered trademarks and the exclusive property of Screen Innovations. Warranty...
  • Page 36 Screen Innovations 9715-B Burnet Rd, Suite 400 Austin, TX 78758 512.832.6939 www.screeninnovations.com v. 1.7 | June 2022...

This manual is also suitable for:

Solo pro 2

Table of Contents