Screen Innovations Solo Installation Instructions Manual page 14

Table of Contents

Advertisement

Screen with SIFI block diagram
Powe
Power
To IP Network
Standard
CAT - 5e or
higher cable
Bus Power
Data Pass-
through Input
485
01
2
c
SDN / Power
485
Programming AC(110v) 485 - with SIFI
Data CAT 5e or better
Power/Data
Output
Supply
Stub length must not exceed 200'
Data Hub
c
c
Device
Device
Device
Device
Device
c
1. Launch Windows File Explorer
2. Click on the "Network" tab
3. Double click on the SIFI, the default web browser will
launch
4. At the landing page, click the three lines in the top
right corner, then click "Settings"
5. Select the "SDN" tab on the top left
6. Press the spyglass to auto discover motors on the
485 network (may have to press it more than once)
7. Click on the motor you want to program
8. Name the motor
9. Right click on the down limit count
10. Move the screen up or down using the buttons in the
popup window
11. Click set to confirm the limit
12. Operate the screen up and then back down to verify
the position of the limit