4.2 Additional recommendations

Relative to pressurised appliances (PED-97/23/EC)
4.2.1 Installation and maintenance
• It is prohibited to install the appliance close to combustible materials or close to the air intake on an adjacent building.
• For some appliances it is imperative to use the protection grate accessory if the installation is located in an unregulated
access area.
• During installation, repair, or maintenance operations it is prohibited to use piping as a step ladder: under stress the
piping could rupture and the coolant could cause serious burns.
• During maintenance of the appliance the composition and condition of the heat transporting fluid will be checked as
will the absence of traces of coolant.
• During the annual appliance seal inspection in compliance with applicable regulations, check that the high and low
pressure switches are correctly connected to the refrigeration circuit and that they cut the electric circuit when triggered.
• During the maintenance phase make sure there are no traces of corrosion or oil stains around the refrigerating
components.
• Before any operations on the refrigerating circuit it is imperative to shut down the appliance and to wait a few minutes
before fitting temperature or pressure sensors. Some equipment such as the compressor and piping can reach
temperatures in excess of 100°C and high pressures which can cause serious burns.
4.2.2 Repairs
• All welding operations are to be carried out by qualified welders
• Piping can only be replaced using copper tube in compliance with NF EN 12735-1 standard.
• Leak detection, pressure test:
- never use oxygen or dry air, there is a risk of fire and explosion,
- use dehydrated nitrogen or a mixture of nitrogen and the coolant indicated on the identification plate,
- the test pressure on the low and high pressure sides must not exceed 42 bar.
• For the high pressure circuit piping using copper pipes of a diameter = or > than 1''5/8, a §2.1 certificate under standard
NF EN 10204 is to be requested from the supplier and kept with the installation technical documents.
• The technical information relative to the safety requirements for the different applicable directives is indicated on
the identification plate. All this information must be recorded on the appliance installation manual which must be
part of the installation technical file: model, code, serial number, maximum and minimum service voltage and service
pressure, year of manufacture, CE marking, manufacturer's address, coolant type and weight, electric parameters,
thermodynamic and acoustic performances.

4.3 Available accessories

Name
Representation

4.4 Recycling

This symbol means that your appliance must not be disposed of as household waste. It will be subject to selective
waste sorting with a view to its reuse, recycling or sale. If it contains substances that are potentially harmful to the
environment, they will be eliminated or neutralised.
Ask your reseller for information about recycling.

5. Troubleshooting

5.1 Displays

Display
Protection of heat
exchanger in cold
mode
High temperature
defect for the
evaporator in
«cooling» mode
9
PAC NET
Designation
Temperature of ST4
sensor too low
Temperature probe
ST3 above 60°C or
evaporator scaled up
Remote control
Cause
Wait for the surrounding
temperature to become
warmer
Clean the evaporator,
if the defect persists,
contact an approved
technician
Technical room kit
Solution
Automatic
Automatic if
temperature probe
ST3 is below 45°C
H0439100.B - EN - 2014-09