5.4.3.
1. Unscrew the plug of the flue gas measurement point.
2. Connect the flue gas analyser.
T001526-A
3. Set the boiler to part load. Press the two B keys
ºCºFh
barPsi
4. Measure the percentage of O
rpm
kWµA
l/min
± 30
T001587-A
5. If this rate does not match the required value, correct the gas/air
6. Check the flame through the flame inspection window.
O
T000933-B
Calenta 25s
Calenta 28c
Calenta 35s
Calenta 40c
O
Calenta 25s
Calenta 28c
Calenta 35s
Calenta 40c

Setting the air/gas ratio (Part load)

WARNING
Ensure that the opening around the sensor is completely
sealed when taking measurements.
simultaneously. The symbol B appears. Press the [-] key several
times until l3 is displayed on the screen.
panel removed).
ratio using the adjustment screw B on the gas valve unit.
Turn the screw B anticlockwise to obtain a lower
4
CO
value.
2
Turn the screw B clockwise to obtain a higher CO
4
value.
The flame must be stable and blue in colour with orange
particles around the edge of the burner.
/CO
control and setting values at part load for G20 (Gas H)
2
2
Boiler type
Setting value
O
(%)
2
5,9 ± 0,4
5,9 ± 0,4
5,5 ± 0,4
5,5 ± 0,4
/CO
control and setting values at part load for G25 (Gas L)
2
2
Boiler type
Setting value
O
(%)
2
5,7 ± 0,4
5,7 ± 0,4
5,2 ± 0,4
5,2 ± 0,4
or CO
in the flue gases (Front
2
2
Checking value
CO
(%)
O
(%)
2
2
8,4 ± 0,2
5,9 ± 0,4
8,4 ± 0,2
5,9 ± 0,4
8,6 ± 0,2
5,5 ± 0,4
8,6 ± 0,2
5,5 ± 0,4
Checking value
CO
(%)
O
(%)
2
2
8,4 ± 0,2
5,7 ± 0,4
8,4 ± 0,2
5,7 ± 0,4
8,7 ± 0,2
5,2 ± 0,4
8,7 ± 0,2
5,2 ± 0,4
5. Commissioning
2
CO
(%)
2
8,4 ± 0,2
8,4 ± 0,2
8,6 ± 0,2
8,6 ± 0,2
CO
(%)
2
8,4 ± 0,2
8,4 ± 0,2
8,7 ± 0,2
8,7 ± 0,2