Equipment Categories; Additional Directives; Factory Test - REMEHA Calenta 25s Installation And Service Manual

High-efficiency wall-hung condensing gas boilers
Table of Contents

Advertisement

Calenta 25s - 28c - 35s - 40c
NZ
040412 - 7600585-01
This means that the boiler complies with the NOx Order and
provisions on clean combustion. The boiler has a gas/air coupling
combined with a fully premixed burner. For this reason, the emission
of NOx and CO is as low as possible.
NZ gas approval (Solar water heater reheating)
This implies that the hot water/heating boiler can operate on reheating
for solar water heaters. The label (solar water heater reheating) is
valid in combination with the connection kit for solar water heaters.
Owing to the possible formation of legionella, the boiler must not be
T001779-B
shut down or the DHW temperature set below 60°C.
1.4.2.
Gas category Gas type
II
, I
2L3P
2H
The boiler is preset in the factory to operate on natural gas G25 (Gas
L).
1.4.3.
Apart from the legal provisions and Directives, the additional
Directives described in these instructions must also be observed.
For all provisions and Directives referred to in these instructions, it is
agreed that all addenda or subsequent provisions will apply at the
time of installation.
1.4.4.
Before leaving the factory, each boiler is set for optimum performance
and tested to check the following items:
4 Electrical safety
4 Adjustment (CO
4 Domestic hot water mode (Only on models with domestic hot water
production)
4 Water tightness
4 Gas tightness
4 Parameter settings

Equipment categories

Connection pressure (mbar)
G20 (Gas H)
20
G25 (Gas L)
25
G31 (Propane) 30/50

Additional Directives

Factory test

)
2
1. Introduction
9