Resolving potential inconsistencies

6.1
Zone
There are two levels of inconsistency warnings:
"Yellow": One or more coordinates of the selected zone are at the
limit of Blaxtair ® performance capacity as validated by Arcure.
"Red": One or more coordinates of the selected zone are beyond the
limits of Blaxtair ® performance capacity as validated by Arcure.
If any of these potential inconsistencies are detected, check that:
All "x" coordinates of the "obstacle" and "pedestrian" detection zones
are above 0.00m and under 2.00m.
The "y" coordinates of the "pedestrian" zone are below 6.00m.
The "y" coordinates for the "obstacles" detection zone are below
3.00m.
23/04/2019
If the zones are slightly outside the recommended
settings (the coordinates have turned yellow in the
editor), it is possible to validate the configuration taking
into account these warnings. In this case, an
inconsistency warning appears when closing the
configuration tool. Confirm that you accept the warning
by selecting the green tick on the warning box that
appears
Validating the configuration without taking into account
red warnings will invalidate the Blaxtair ® performance
guarantee and the system will adjust the zones based
on the maximum permitted zones, not the zones
defined by the installer.