Increasing coordinate x moves the Sensor Head to the right in the
outlined area;
Increasing coordinate y moves the Sensor Head down in the outlined
area;
When the angle is 0°, the Sensor Head is angled towards the front
of the machine;
When the angle is 90°, the Sensor Head is angled to the left of the
machine;
When the angle is 180°, the Sensor Head is angled to the back of
the machine;
When the angle is 270°, the Sensor Head is angled to the right of the
machine.
3.10

Alarm types

The operator is notified of any detection by alarms.
.
To activate/deactivate the alarm signal when in forward or
neutral or reverse gear, check/uncheck the box « detection all
the time ».
To activate/deactivate the alarm signal in accordance with the
desired mode (most of the time in reverse gear), check/uncheck
the box « detection if input 1 is active ».
For MR90 configurations, when the head films the scene behind
the operator, selecting the alarm to sound in "detection if input
1 is active". Make sure that the 'reverse' wire (Green wire) is
connected.