External Enable Input; Fault Output; Figure 5-6. Electrical Characteristics Of Opto-Isolated Input; Figure 5-7. Electrical Characteristics Of Opto-Isolated Output - Aerotech BA-SineDrive Series User Manual

Table of Contents

Advertisement

Technical Details

5.3.5. External Enable Input

The external enable is an opto-isolated input.
characteristics of this input.
To use an external power supply that is greater than 9 volts, a resistor must be added to
input feed. Place the resistor in series with each input to limit the current to a safe 20mA.

5.3.6. Fault Output

The BAS has a fault output that is opto-isolated. The electrical characteristics of this
output are shown in the Figure 5-7.
5-8
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
JP2
P1
6
Input Common
5
Any Opto-Isolated Input
Opto-Coupler PS2501-4
Figure 5-6.
Electrical Characteristics of Opto-Isolated Input
BA-SineDrive
510 OHM
Opto-Coupler - PS2501 – 4
Figure 5-7.
Electrical Characteristics of Opto-Isolated Output
Aerotech, Inc.
BA SineDrive User's Manual
shows the electrical
Figure 5-6
1.2K
3
1
390 OHM
BA SINE DRIVE
+V
R
ext
P1
10
Fault Output
9
Output Common = To
signal common of external
circuit
+5
10K OHM
Version 1.4

Advertisement

Table of Contents
loading

Table of Contents