Faema E71 E Engineer's Manual page 48

Hide thumbs Also See for E71 E:
Table of Contents

Advertisement

MALFUN.
DESCRIPTION
CODE
Group x boiler heating
(x)52*
timeout - 20 minutes
(x = 1, 2, 3, 4)
Note: Group 1 is to the far left.
Steam thermocouple out of
(x) 53*
range.
DX > 053; SX > 153
Boiler overpressure alarm.
058
Boiler: Refill timeout
059
- 15 minutes.
Boiler-level signal errors.
060
Coffees dispensed for MM1
with flow under the limit
062
(3 consecutive coffees
dispensed).
Coffees dispensed referred
063
to MM1 with flow over the
limit
(3 consecutive coffees
dispensed).
Coffees dispensed referred
064
to MM2 with flow under the
limit
(3 consecutive coffees
dispensed).
Coffees dispensed referred
065
to MM2 with flow over the
limit
(3 consecutive coffees
dispensed).
POSSIBLE CAUSES
• T he group x boiler safety
thermostat has been
triggered
• The resistance is
interrupted (cabling defect).
• Triac board fault.
• Thermocuple
disconnected
• Wrong configuration
during standard data in-
sertion.
• R esistanc
alwayspowered.
• Temperature sensor out
of range.
• No water
• Refill EV failure
• Wiring interrupted
• Card failure.
• Electrical fault.
• Leakage to earth.
• coffee filter blocked
• coffee type changed
• qref calibration wrong
• grind too fine,
excessive dose ground.
• coffee type changed
• qref calibration wrong
• grinding too coarse
• grinder/dispenser
blocked, insufficient
dose of ground coffee.
• coffee filter blocked
• coffee type changed
• qref calibration wrong
• grind too fine,
excessive dose ground.
• coffee type changed
• qref calibration wrong
• grinding too coarse
• grinder/dispenser
blocked, insufficient
dose of ground coffee.
43 EN
VERIFICATIONS and SOLUTIONS
• C heck if the safety thermostat of the group x boiler
has been triggered, and reset it if necessary
• C heck if there are interruptions or detached
fastons on the cabling
• C heck that the group x boiler resistance is not
interrupted and replace it if necessary
• R eplace Triac board.
• E nter in the programming mode and insert the
correct standard data..
• C heck connections.
• R eplace the steam temperature probe.
• C heck cabling
• R eplace the sensor.
• C heck water is supplied from the main line.
• R eplace the refill EV.
•Check cabling.
• R eplace the card.
• C heck wiring.
• C heck, by activating the components individually
on the manual control panel, that the level signal
does not show any anomalies (%).
• wash the group
• clean/replace the coffee filter
• use a coarser grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
• check that there are no external elements in the
grinders
• check that the measure grinder is working (pick-
up current and fuses)
• use a finer grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
• wash the group
• clean/replace the coffee filter
• use a coarser grind
• calibrate the machine correctly on the basis of
the coffee/recipe.
• check that there are no external elements in the
grinders
• check that the measure grinder is working (pick-
up current and fuses)
• use a finer grind
• calibrate the machine correctly on the basis of
the coffee/recipe.