IBM Power System POWER7 Series Common Service Procedures page 45

Hide thumbs Also See for Power System POWER7 Series:
Table of Contents

Advertisement

If the rightmost hexadecimal digit of offset 000182 is 2, then the unit address is hexadecimal offset 192
- 195
Record this address information. Return to the procedure that sent you here, if one.
Display Hexadecimal Report for Resource
Name
Type
STORAGE
6512
Offset
0 1 2 3 4 5 6 7 8 9 A B C D E F
000180
D0007800 65120001 34000620 1100FFFF
000190
FFFFFFFF 31090000 00001100 03C00000
0001A0
00000000 00000000 00000000 00000000
0001B0
00000000 00000000 00000000 00000000
0001C0
00000000 00000000 00000000 E0000008
0001D0
00000000 00000000 00000000 00000000
0001E0
00000018 00000002 E00401F0 10002000
0001F0
00000000 40000000 00000000 000002CC
000200
CCCC0000 00000000 00800000 00000000
000210
08100000 00000000 F0200040 00800000
000220
00000000 04000000 08000040 E000E221
000230
800084F3 00000002 0000001B 110003C0
More...
Press Enter to continue.
F3=Exit
F12=Cancel
Figure 10. Example of hexadecimal report for resource offset location (where the rightmost hexadecimal digit of offset
000182 is 8)
Display Hexadecimal Report for Resource
Name
Type
STORAGE
571A
Offset
0 1 2 3 4 5 6 7 8 9 A B C D E F
000180
F8407200 F5F7F1C1 F0F0F0F1 3400031D
000190
00233104 00FFFFF4 F0F0F0F0 F0F0F0F0
0001A0
1104E255 F0F0F0F0 F0F0F0F0 40404040
0001B0
40404000 00FF0000 04440000 A1D0038D
0001C0
0713000C 00000000 00000000 70000200
More...
Press Enter to continue.
F3=Exit
F12=Cancel
Figure 11. Example of hexadecimal report for resource offset location (where the rightmost hexadecimal digit of offset
000182 is 2)
6. Using hexadecimal arithmetic, add the value in offsets 170 - 173, the value in offsets 174 - 177, and
00000002. For example, 000001C8 + 00000410 + 00000002 = 000005DA.
If the value of the rightmost hexadecimal digit at this offset is 8: Using hexadecimal arithmetic, add
0000000A to the offset you calculated. This will be the location of the unit address in the form
abcdefgh. For example, 00005DA + 0000000A = 000005E4.
If the value of the rightmost hexadecimal digit at this offset is 2: Using hexadecimal arithmetic, add
00000010 to the offset you calculated. This will be the location of the unit address in the form
abcdefgh. For example, 00005DA + 00000010 = 000005EA.
Record this address information. If you were sent here from another procedure, return to the
procedure that sent you here.
This ends the procedure.
Serial
Model
Number
001
10-4294009
EBCDIC
}...............
.............{..
................
................
................
................
...........0....
.... ...........
................
........0.. ....
........... ..S.
...3...........{
Serial
Model
Number
001
10-4294009
EBCDIC
8 ..571A0001....
.......400000000
..S.00000000
................
Resource
Name
SI05
Resource
Name
DC01
..........}..
Common service procedures
31